Abstract
The present work reports results from an extensive set of measurements which has been performed in order to formulate standard method to remove temperature changes from impedance measurements. The other issue addressed here is the investigation of influence of boundary condition and temperature changes on electromechanical impedance measurement for structural member. Due to electromechanical coupling, changes in dynamic characteristics can be seen in electrical impedance of piezoelectric transducer. Two different systems have been used during this measurement process. System based on FBG sensors has been used for temperature changes measurement while PZT transducers mounted on the structure with impedance analyser were used for electrical parameters measurement. During research electrical impedance and resistance of piezoelectric transducer were measured in order to analyze changes in amplitude of peaks and the frequency shift of peaks due to temperature variations and different configurations of the beam.
Export citation and abstract BibTeX RIS