Initial Systolic Time Interval (ISTI) as a Predictor of Intradialytic Hypotension (IDH)

, , and

Published under licence by IOP Publishing Ltd
, , Citation J D Biesheuvel et al 2013 J. Phys.: Conf. Ser. 434 012036 DOI 10.1088/1742-6596/434/1/012036

1742-6596/434/1/012036

Abstract

In haemodialysis treatment the clearance and volume control by the kidneys of a patient are partially replaced by intermittent haemodialysis. Because this artificial process is performed on a limited time scale, unphysiological imbalances in the fluid compartments of the body occur, that can lead to intradialytic hypotensions (IDH). An IDH endangers the efficacy of the haemodialysis session and is associated with dismal clinical endpoints, including mortality. A diagnostic method that predicts the occurrence of these drops in blood pressure could facilitate timely measures for the prevention of IDH. The present study investigates whether the Initial Systolic Time Interval (ISTI) can provide such a diagnostic method. The ISTI is defined as the time difference between the R-peak in the electrocardiogram (ECG) and the C-wave in the impedance cardiogram (ICG) and is considered to be a non-invasive assessment of the time delay between the electrical and mechanical activity of the heart. This time delay has previously been found to depend on autonomic nervous function as well as preload of the heart. Therefore, it can be expected that ISTI may predict an imminent IDH caused by a low circulating blood volume. This ongoing observational clinical study investigates the relationship between changes in ISTI and subsequent drops in blood pressure during haemodialysis. A registration of a complicated dialysis showed a significant correlation between a drop in blood pressure, a decrease in relative blood volume and a substantial increase in ISTI. An uncomplicated dialysis, in which also a considerable amount of fluid was removed, showed no correlations. Both, blood pressure and ISTI remained stable. In conclusion, the preliminary results of the present study show a substantial response of ISTI to haemodynamic instability, indicating an application in optimization and individualisation of the dialysis process.

Export citation and abstract BibTeX RIS

Please wait… references are loading.
10.1088/1742-6596/434/1/012036