This site uses cookies. By continuing to use this site you agree to our use of cookies. To find out more, see our Privacy and Cookies policy.
The following article is Open access

Randomized benchmarking of single- and multi-qubit control in liquid-state NMR quantum information processing

, and

Published 23 January 2009 Published under licence by IOP Publishing Ltd
, , Citation C A Ryan et al 2009 New J. Phys. 11 013034 DOI 10.1088/1367-2630/11/1/013034

1367-2630/11/1/013034

Abstract

Being able to quantify the level of coherent control in a proposed device implementing a quantum information processor (QIP) is an important task for both comparing different devices and assessing a device's prospects with regards to achieving fault-tolerant quantum control. We implement in a liquid-state nuclear magnetic resonance QIP the randomized benchmarking protocol presented by Knill et al (2008 Phys. Rev. A 77 012307). We report an error per randomized π/2 pulse of 1.3±0.1×10−4 with a single-qubit QIP and show an experimentally relevant error model where the randomized benchmarking gives a signature fidelity decay which is not possible to interpret as a single error per gate. We explore and experimentally investigate multi-qubit extensions of this protocol and report an average error rate for one- and two-qubit gates of 4.7±0.3×10−3 for a three-qubit QIP. We estimate that these error rates are still not decoherence limited and thus can be improved with modifications to the control hardware and software.