This site uses cookies. By continuing to use this site you agree to our use of cookies. To find out more, see our Privacy and Cookies policy.

High-precision thermal neutron diffusion parameters for Plexiglass

and

Published under licence by IOP Publishing Ltd
, , Citation K Drozdowicz and U Woznicka 1987 J. Phys. D: Appl. Phys. 20 985 DOI 10.1088/0022-3727/20/8/001

0022-3727/20/8/985

Abstract

The thermal neutron diffusion parameters for Plexiglass have been determined with high accuracy. The classic pulsed neutron experiment based on the concept of variable geometric buckling has been performed (the buckling B2 being from 0.036 to 1.234 cm-2). Details on the treatment of data are given. The following values of the parameters have been obtained at the temperature of 20 degrees C: v Sigma a=(4120+or-30) s-1, D0=(37312+or-100) cm2 s-1, C=(6192+or-457) cm4 s-1, F=(1203+or-400) cm6 s-1. They are compared with the values reported by other authors. The influence of experimental conditions on the final results as well as some theoretical problems concerning diffusion cooling are discussed.

Export citation and abstract BibTeX RIS