Reliability and performance studies of DC-DC conversion powering scheme for the CMS pixel tracker at SLHC

, , and

Published 6 December 2010 Published under licence by IOP Publishing Ltd
, , Citation A Todri et al 2010 JINST 5 C12010 DOI 10.1088/1748-0221/5/12/C12010

1748-0221/5/12/C12010

Abstract

The upgrades of the Large Hadron Collider (LHC) introduce a significant challenge to the power distribution of the detectors. DC-DC conversion is the preferred powering scheme proposed to be integrated for the CMS tracker to deliver high input voltage levels and performing a step-down conversion nearby the detector modules. In this work, we propose a step-up/step-down powering scheme by performing voltage step up at the CAEN supply unit and voltage step down near the detector. We designed step-up converters and investigate the pixel performance and power loss on the FPIX power distribution system. Tests are performed using the PSI46 pixel readout chips on a forward pixel panel module and the DC-DC converters developed at CERN and Fermilab. Reliability studies include the voltage drop measurements on the readout chips and the power supply noise generated from the converter. Performance studies include pixel noise and threshold dispersion results. Comparison between step-down only and step-up/step-down conversion powering schemes are provided.

Export citation and abstract BibTeX RIS

Please wait… references are loading.