New J. Phys. 11 (2009) 013001
doi:10.1088/1367-2630/11/1/013001

A quantum imager for intensity correlated photons

D L Boiko1,2,6, N J Gunther3, N Brauer1, M Sergio1, C Niclass1, G B Beretta4 and E Charbon1,5

1 Ecole Polytechnique Fédérale de Lausanne, 1015, Lausanne, Switzerland
2 Centre Suisse d'Electronique et de Microtechnique SA, 2002, Neuchâtel, Switzerland
3 Performance Dynamics, 4061 East Castro Valley Blvd, Suite 110, Castro Valley, CA, USA
4 HP Laboratories, 1501 Page Mill Road, Palo Alto, CA, USA
5 Delft University of Technology, 2628CD, Delft, The Netherlands

6 Author to whom any correspondence should be addressed.

E-mail: dmitri.boiko@csem.ch

Received 4 September 2008
Published 7 January 2009

Abstract. We report on a device capable of imaging second-order spatio-temporal correlations g(2)(x, τ) between photons. The imager is based on a monolithic array of single-photon avalanche diodes (SPADs) implemented in CMOS technology and a simple algorithm to treat multiphoton time-of-arrival distributions from different SPAD pairs. It is capable of 80 ps temporal resolution with fluxes as low as 10 photons s–1 at room temperature. An important application might be the local imaging of g(2) as a means of confirming the presence of true Bose–Einstein macroscopic coherence (BEC) of cavity exciton polaritons.

Recent experiments [1]–[4] have reported the Bose–Einstein condensation (BEC) phase transition in a polariton system in a semiconductor microcavity. The macroscopic quantum degeneracy is typically detected by probing the statistical properties of light emitted from a microcavity, under the presumption that the statistics of the exciton polaritons are faithfully transferred to the emanating photons.

It has been further assumed that observation of the interference fringes similar to those in Michelson or Young interferometers (figure 1(a)) is sufficient to establish the fact of macroscopic coherence in polariton systems [1, 4, 5]. Two points on the wave front separated by a distance x12 produce an intensity pattern I_1+I_2+2 \sqrt{I_1I_2}\vert g^{(1)}(\mathbf{x}_{12},\tau)\vert \cos(\Delta \varphi_{12}) , such that the fringe visibility measures the magnitude of the first-order correlation function. But simply measuring this quantity alone is ambiguous because a coherent light source (e.g. a photon laser or decaying polariton BEC) can exhibit the same first-order correlations as a chaotic (or thermal) light source (e.g. Hg–Ar discharge lamp in figure 1(b)). Table 1 shows that proper disambiguation of a coherent state also requires measurement of the second-order correlation function g^{(2)}(\mathbf{x}_{12}, \tau) = \frac{\langle I_1(t) \, I_2( t+\tau)\rangle}{\langle I_1(t)\rangle \langle I_2(t) \rangle } associated with intensity noise correlations. Here, I1, 2(t) is the light intensity at a point \pm \frac{1}{2}\,{\bf x}_{12} and time t. The minimal condition to confirm the BEC phase transition in a polariton system then becomes g(1)(x, 0) = g(2)(x, 0) = 1 (third column of table 1). So far, the very few theoretical and experimental studies of the second-order correlations in a polariton system have been limited to the k = 0 point in the momentum space (in the lateral cavity direction), reporting thus a spatially averaged value of g(2)(0) and ignoring the fact that two-dimensional (2D) BEC can be achieved only in spatially confined systems. As a consequence, the model of [6] predicts increasing correlation peak height g(2)(0) with polariton number caused by the strong scattering effects above the critical threshold density. Such behaviour for polaritons at k = 0 has been confirmed in [7], whereas the experimental results of [8] disagree with such behaviour. To confirm the BEC phase transition in a polariton system, one needs to distinguish the presence of both coherent condensate (g(1) = g(2) = 1) and thermal noncondensate (g(1)g(2)) fractions, which can be achieved by local measurement of the first- and second-order correlations. However, the small dimensions of the polariton distribution in the microcavity, mean that such measurements must be capable of resolving a spatial dependence in g(2). All these requirements demand an integrated monolithic photon detector, like a camera, but capable of imaging intensity noise correlations.

Figure 1

Figure 1. Interference fringes (a) at λ = 770 nm wavelength used to verify the BEC of polaritons in GaAs microcavity (reproduced from [4], reprinted with permission from AAAS) and (b) at λ = 546 nm measured for the green line of pulsed Hg–Ar discharge lamp.

Table 1. Values of first- and second-order correlation functions for incoherent, coherent and thermal light states.
Function Incoherent Coherent Chaotic
g(1)(x, 0) 0 1 1
g(2)(x, 0) 1 1 2

In this paper, we present an imaging device allowing the second-order (intensity) correlations of a field to be probed locally. The current implementation comprises a 4×4 silicon array of single-photon avalanche diodes (SPADs) implemented in 0.35 μm CMOS technology [9]. The device incorporates on-chip high bandwidth I/O circuitry (figure 2) for off-chip data processing of multiphoton arrivals. We demonstrate the operational performance of our monolithic g(2)-imager in a miniature replication of the Hanbury Brown and Twiss (HBT) stellar interferometer [10].

Figure 2

Figure 2. Exploded micrograph of the 4×4 SPAD array.

Each pixel in our SPAD array is based on an avalanche photodiode operating in the Geiger mode. The 3.5 μm-diameter active region of a SPAD n-well pixel consists of a p + –n junction reverse-biased above its breakdown voltage. When a photon is absorbed in the multiplication region, an avalanche is triggered with a certain probability. The measured single photon detection probability of such 0.35 μm-CMOS SPAD pixels is 25% at 546 nm wavelength and 4 V excess voltage above the breakdown threshold. (The detection probability is 40% at the peak sensitivity wavelength 450 nm [9].) The avalanche breakdown is subsequently quenched by an on-chip ballast resistor, which is used to read out the photodetection events. Its value defines the dead time of the detector which is 15 ns for each SPAD pixel of the 4×4 array considered here. The chip comprises built-in high-bandwidth electronics to convert Geiger pulses into digital signals for off-chip data processing. This design drastically improves the signal-to-noise ratio. At room temperature, the lowest detectable photon flux is set by the dark count rate (DCR) of SPADs in the 5–10 Hz range. Such low DCR is achieved by using small n-wells of diameter 3.5 μm. The lowest detectable photon flux density in our experiments is ~108 photons s cm–2, well below the level in polariton BEC experiments. The array pitches are 30 μm horizontal and 43 μm vertical. All 16 detectors in the array have separate parallel outputs so that \left({16 \atop 2} \right) = 120 simultaneous pairwise measurements are possible at a temporal resolution limited by the SPAD jitter characteristics (80 ps).

The pairwise intensity noise correlations g(2)(xij, τ) are computed using an external four-channel 6 GHz bandwidth digital oscilloscope (Wavemaster 8600A, LeCroy) by programming it with an algorithmic version of equation (1):

Equation (1)

where integers i,j (ij) enumerate detector pixels, Xi and Xj are discrete random variables whose values 0 (no event) or 1 (photon detection) correspond to the binary data stream (figure 3(a)) emanating from any pair of detectors Di and Dj, respectively. The spatial lag xij is set by the separation of the detector pair within the SPAD array. Time-lag increments τ = lT are set by multiples of temporal resolution T, where NT is the width of measurement window and M is the overall number of measurements series.

Figure 3

Figure 3. Comparison of single-photon and multiphoton measurements. (a) Traces from two detectors at 5 MHz count rate. Standard histogram of delayed single-photon arrivals shows a large number of lost detections. (b) Computed g(2) based on multiphoton arrivals (green) and the standard technique (red) showing the impact of lost detections at count rates μ~2.5 MHz at each detector and the width of measurement window NT  =  100 ns.

Unlike conventional detection methods based on start-stop timing histograms of delayed single photon arrivals (figure 3(a)), our approach implements properly normalized multiphoton distribution which is robust against missing detection events, the impact of Poisson-like distribution decay proptoexp(–μτ) at large τ and intensity modulation. Equation (1) permits any count rates and temporal window of interest and does not require a statistical hypothesis to normalize g(2). Figure 3(b) shows the benefits of our technique by comparing g(2)(τ) measurements of incoherent broad-band light using multiphoton arrivals and the standard two-photon histogram.

In figure 3(b), for the standard approach based on time-delayed coincidence events, the histogram was acquired and then normalized assuming that at the lag τ = 0 there should be no correlations for incoherent light source (i.e. assuming that g(2)(0) = 1). We shall remind readers that a probability distribution of time intervals between two consecutive photons is p(0|τ) = μ exp(–μτ) for a Poisson process [11, 12] and that for a multi-mode Gaussian (chaotic light) and a coherent (Poisson statistics) states these distributions are the same [13]. Therefore, when normalized in such way, the standard method shows the onset of Poisson distribution g(2)(τ) = p(0|τ)/μ≊1–μ|τ| for sufficiently large time lag |τ|~0.1 μ–1 but yet small μ|τ| product. (For μ|τ|~1 and higher, the standard method shows the exponential decay g(2)(τ) = exp (–μ|τ|).) Thus in figure 3(b), the average count rate at detectors is μ = 2.5 MHz, and for τ = 50 ns, the error is Δg(2)~0.13. The conventional procedure is thus limited to small count rate and temporal window width product. At the same time, our approach produces the correct correlations independent of the measurement interval NT and the photon flux intensity.

The g(2)-imager was tested by measuring the statistical properties of an extended thermal light source. As a model system for a quasi-monochromatic chaotic light source, we used a Hg–Ar spectral wavelength calibration lamp (bulb CAL-2000-B, Ocean Optics) with U-folded discharge and cold cathode. This lamp, designed for operation in the ac regime, also operated well with a dc power supply (160 V @ 15 mA). To start the discharge, we used the original ac power supply of CAL2000 source, which was connected in parallel with a dc source via a filter (2H inductance) such that the ac supply was gradually turned off, whereas the dc source was gradually turned on.

The light emitted by the lamp was transmitted through a 10 nm bandpass filter (FL543.5–10, Thorlabs), which keeps only the emission at the green line of mercury (546 nm). The light then was injected into a 1 m long multimode fiber (figure 4(a)) with core diameter w = 200 μm. The other end of the fiber was used to illuminate the SPAD array placed in the far field zone of the fiber end, at a distance L = 2 cm from the fiber (figure 4(a)). The numerical aperture of the fiber (NA = 0.22) assumes that the whole 4×4 SPAD array is over illuminated. Such extended thermal light source is of the angular width w/L = 10–2 rad and exhibits first-order correlations g(1) (figure 1(b)), when the SPAD array is replaced by a Young double-pinhole interferometer (not shown in the figure).

Figure 4

Figure 4. (a) SPAD array configured as miniature HBT interferometer for measuring 200 μm (b) correlations between adjacent detectors (x5, 6 = 30 μm) and (c) extreme diagonal detectors (x0, 15 = 158 μm). (d) Measured (points) and calculated (curve) second-order in function of detector separation. The micrograph inset shows the position of detectors within the array. (e) Imaged second-order correlation maxima along the row of array in (d). It is assumed that g(2) = 2 along the diagonal.

The second-order spatio-temporal correlations for a nonpolarized single-mode chaotic light source are determined by the first-order correlations [11, 14, 15] with coherence time \tau_{\rm c}=2\sqrt{2 \pi \ln2}/\Delta \omega due to the inhomogeneous broadening Δω (FWHM) of the emission line

Equation (2)

where the second term in the right-hand side takes into account the decorrelation effects due to unpolarized light (the coefficient 1/2), the zero-delay degree of spatial coherence and the Gaussian profile of the delayed first-order correlation function for an inhomogeneously broadened line.

To examine the temporal correlations, we used detector pairs in the middle of the array as well pairs at diagonally opposite corners, thus providing correlations g(2)(xij, τ) between two different regions separated by 30 and 158 μm, respectively. At small separation (figure 4(b)), the data show an excess of coincidences g(2)(x5, 9, 0) = 1.25. At large distance, detector counts are uncorrelated (figure 4(c)).

At temporal resolution of the scope T = 1 ns, the measured coherence time τc is 5.2 ns such that the impact of integration effects on measured correlation peak width and height is less than 2% [16]. The corresponding linewidth of the source is 130 MHz (FWHM), which is less than the Doppler width of the green line of Hg and can be attributed to the Dicke linewidth narrowing due to the buffering effect of Ar in the lamp bulb.

The spatial oscillations of g(2)(xij, 0) due to the spatial coherence factor in (2) were measured by selecting detector pairs from a row of the array (D1–D13 row in figure 2) with detector separation 30, 60 and 90 μm. Figure 4(d) shows the correlation excess at zero-delay is well fitted by the sinc function in equation (2), yielding the angular width of the source 0.9×10–2 rad, close to the estimated value.

Being limited by the number of acquisition channels, we were able to record simultaneous correlations between four independent detectors. In figure 4(e), g(2)(xij, 0) measured along the array row is plotted as a pairwise correlation map g(2)(i, j). In this image map, the spatial oscillations of the coherence factor are clearly visible.

In conclusion, we have presented a g(2)-imager built with conventional CMOS technology, which is capable of measuring second-order spatio-temporal correlated photons and thereby offers an important means for verifying the existence of a BEC state of cavity exciton polaritons. Future work will include the development of larger arrays of SPADs, the integration of on-chip data processing based on equation (1), and the extension to other g(2)-imaging applications.

Acknowledgment

This research was supported, in part, by a grant of the Swiss National Science Foundation.

References

[1]
Kasprzak J et al 2006 Nature 443 409–14 
CrossRefPubMed
[2]
Deng H, Press D, Götzinger S, Solomon G S, Hey R, Ploog K H and Yamamoto Y 2006 Phys. Rev. Lett. 97 146402 
CrossRefPubMed
[3]
Christopoulos S et al 2007 Phys. Rev. Lett. 98 126405 
CrossRefPubMed
[4]
Balili R, Hartwell V, Snoke D, Pfeiffer L and West K 2007 Science 316 1007–10 
CrossRefPubMed
[5]
Snoke D W 2003 Phys. Status Solidi b 238 389–96 
CrossRef
[6]
Schwendimann P and Quattropani A 2008 Phys. Rev. B 77 085317 
CrossRef
[7]
Kasprzak J, Richard M, Baas A, Deveaud B, André R, Poizat J-Ph and Le Si Dang 2008 Phys. Rev. Lett. 100 067402 
CrossRefPubMed
[8]
Deng H, Weihs G, Santori Ch, Bloch J and Yamamoto Y 2002 Science 298 199–202 
CrossRefPubMed
[9]
Niclass C, Sergio M and Charbon E 2006 Proc. SPIE Opt. East (Boston) vol 6372  (Bellingham, WA: SPIE Optical Engineering Press) p 63720S 
[10]
Hanbury Brown R and Twiss R Q 1956 Nature 178 1046–8 
CrossRef
[11]
Glauber R J 2007 Ann. Phys. Lpz. 16 6–24 
CrossRef
[12]
Saleh B E A 1973 J. Phys. A: Math. Nucl. Gen. 6 L161–4 
IOPscience
[13]
Arecchi F T 1965 Measurement of the statistical distribution of Gaussian and laser sources Phys. Rev. Lett. 15 912–6 
CrossRef
[14]
Glauber R J 1963 Phys. Rev. 130 2529 
CrossRef
[15]
Glauber R J 1963 Phys. Rev. 131 2766 
CrossRef
[16]
Scarl D B 1966 Phys. Rev. Lett. 17 663 
CrossRef