Vessel calibre and haemoglobin effects on pulse oximetry

M P McEwen1,2, G P Bull2 and K J Reynolds1

Show affiliations


Despite its success as a clinical monitoring tool, pulse oximetry may be improved with respect to the need for empirical calibration and the reports of biases in readings associated with peripheral vasoconstriction and haemoglobin concentration. To effect this improvement, this work aims to improve the understanding of the photoplethysmography signal—as used by pulse oximeters—and investigates the effect of vessel calibre and haemoglobin concentration on pulse oximetry. The digital temperature and the transmission of a wide spectrum of light through the fingers of 57 people with known haemoglobin concentrations were measured and simulations of the transmission of that spectrum of light through finger models were performed. Ratios of pulsatile attenuations of light as used in pulse oximetry were dependent upon peripheral temperature and on blood haemoglobin concentration. In addition, both the simulation and in vivo results showed that the pulsatile attenuation of light through fingers was approximately proportional to the absorption coefficients of blood, only when the absorption coefficients were small. These findings were explained in terms of discrete blood vessels acting as barriers to light transmission through tissue. Due to the influence of discrete blood vessels on light transmission, pulse oximeter outputs tend to be dependent upon haemoglobin concentration and on the calibre of pulsing blood vessels—which are affected by vasoconstriction/vasodilation. The effects of discrete blood vessels may account for part of the difference between the Beer–Lambert pulse oximetry model and empirical calibration.


PACS

87.80.-y Biophysical techniques (research methods)

87.15.N- Properties of solutions of macromolecules

87.14.E- Proteins

Subjects

Instrumentation and measurement

Medical physics

Biological physics

Dates

Issue 9 (September 2009)

Received 22 December 2008, accepted for publication 22 June 2009

Published 27 July 2009


A Corrigendum for this article has been published in 2010 Physiol. Meas. 31 727


  1. Vessel calibre and haemoglobin effects on pulse oximetry

    M P McEwen et al 2009 Physiol. Meas. 30 869

  2. A dual thickness spatial system for determining optical coefficients from scattering media

    S F Baker et al 2004 Meas. Sci. Technol. 15 501

  3. Kinks in dipole chains

    J M Speight and Y Zolotaryuk 2006 Nonlinearity 19 1365

  4. Probing electrical properties of oriented DNA by conducting atomic force microscopy

    Lintao Cai et al 2001 Nanotechnology 12 211

  5. Good enough to eat

    Elizabeth Swinbank 2004 Phys. Educ. 39 52

  6. Positron-hydrogen scattering at intermediate energies using the close-coupling approximation

    M Mukherjee et al 1990 J. Phys. B: At. Mol. Opt. Phys. 23 757

  7. Localization of sentinel nodes in breast cancer: novel method and device to help pen marking of active nodes during gamma camera imaging

    Mikko S Laasanen et al 2005 Phys. Med. Biol. 50 N49

  8. Sideband structure in angle-resolved electron spectra from laser-assisted Auger decay generated by ultra-short pulses

    A K Kazansky and N M Kabachnik 2009 J. Phys. B: At. Mol. Opt. Phys. 42 121002

  9. Excited-state imaging of cold atoms

    David V Sheludko et al 2007 J. Phys.: Conf. Ser. 80 012040

  10. Ionization cross section ratios of rare-gas atoms (Ne, Ar, Kr and Xe) by electron impact from threshold to 1 keV

    Ataru Kobayashi et al 2002 J. Phys. B: At. Mol. Opt. Phys. 35 2087

View by subject




Export






Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.