Stroke volume response during exercise measured by acetylene uptake and MRI

Herman Groepenhoff, Sebastiaan Holverda, J Tim Marcus, Pieter E Postmus, Anco Boonstra and Anton Vonk-Noordegraaf

Show affiliations


The intra-breath technique to measure acetylene absorption offers the possibility to determine augmentation of the pulmonary blood flow per heart beat (QC) as an estimate of the stroke volume response during exercise. However, this method has not been compared with a validated test until now. Therefore, the aim of this study was to compare QC with stroke volume (SVMRI) determined by magnetic resonance imaging (MRI) at rest and during exercise in healthy subjects and patients. For this purpose, ten healthy subjects and ten patients with idiopathic pulmonary arterial hypertension (iPAH) with expected impaired stoke volume response during exercise were measured by both methods. Exercise-induced changes in QC and SVMRI were correlated in healthy controls (r = 0.75, p < 0.05). Compared to healthy controls, QC increased less during exercise in iPAH patients (11 ± 17 ml versus 33 ± 12 ml, p < 0.05). A similar difference in stroke volume response to exercise between the two groups was measured by MRI (−0.6 ± 8 ml versus 23 ± 12 ml, p < 0.05, respectively). Hence, intra-breath and MRI measurements showed similar differences in exercise-induced changes in stroke volume between controls and patients. From these results it can be concluded that the intra-breath measurement of acetylene absorption might be of value as a non-invasive tool to estimate stroke volume augmentation during exercise and can detect differences in stroke volume responses between iPAH patients and healthy subjects.


PACS

87.61.Tg Clinical applications

87.19.Hh Cardiac dynamics

87.19.X- Diseases

87.19.U- Hemodynamics

Subjects

Biological physics

Medical physics

Dates

Issue 1 (January 2007)

Received 25 April 2006, accepted for publication 24 October 2006

Published 17 November 2006



  1. Stroke volume response during exercise measured by acetylene uptake and MRI

    Herman Groepenhoff et al 2007 Physiol. Meas. 28 1

  2. The apparent shape of a rotating charged black hole, closed photon orbits and the bifurcation set A4

    A de Vries 2000 Class. Quantum Grav. 17 123

  3. Accurate pyrometry with microsecond time resolution

    L Coslovi et al 1979 J. Phys. E: Sci. Instrum. 12 216

  4. A measure of the information content of EIT data

    Andy Adler et al 2008 Physiol. Meas. 29 S101

  5. Synthetic-aperture imaging from high-Doppler-resolution measurements

    Brett Borden and Margaret Cheney 2005 Inverse Problems 21 1

  6. Radiation quantities and units—understanding the sievert

    P J Allisy-Roberts 2005 J. Radiol. Prot. 25 97

  7. Growth of a Bose-Einstein condensate: a detailed comparison of theory and experiment

    M J Davis and C W Gardiner 2002 J. Phys. B: At. Mol. Opt. Phys. 35 733

  8. Inverse scattering for the Laplace–Beltrami operator with complex electromagnetic potentials and embedded obstacles

    Stephen O'Dell 2006 Inverse Problems 22 1579

  9. Use of data-driven phase space models in assessing the strength of a bolted connection in a composite beam

    J M Nichols et al 2004 Smart Mater. Struct. 13 241

  10. Topological dimension and local coordinates from time series data

    D S Broomhead et al 1987 J. Phys. A: Math. Gen. 20 L563

Related review articles

What's this?
View review articles related to this research to gain an insight into the key trends in this subject area. Related review articles are selected based on PACS/MSC codes, and are no more than three years old.

  1. Physics of magnetic resonance imaging: from spin to pixel
  2. Interaction of MRI field gradients with the human body

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.