Variability in time delay between two models of pulse oximeters for deriving the photoplethysmographic signals

Jong Yong A Foo1, Stephen J Wilson1, Carolyn Dakin2, Gordon Williams2, Margaret-Anne Harris2 and David Cooper2

Show affiliations


Pulse oximetry is commonly used as an arterial blood oxygen saturation (SaO2) measure. However, its other serial output, the photoplethysmography (PPG) signal, is not as well studied. Raw PPG signals can be used to estimate cardiovascular measures like pulse transit time (PTT) and possibly heart rate (HR). These timing-related measurements are heavily dependent on the minimal variability in phase delay of the PPG signals. Masimo SET® Rad-9™ and Novametrix Oxypleth oximeters were investigated for their PPG phase characteristics on nine healthy adults. To facilitate comparison, PPG signals were acquired from fingers on the same hand in a random fashion. Results showed that mean PTT variations acquired from the Masimo oximeter (37.89 ms) were much greater than the Novametrix (5.66 ms). Documented evidence suggests that 1 ms variation in PTT is equivalent to 1 mmHg change in blood pressure. Moreover, the PTT trend derived from the Masimo oximeter can be mistaken as obstructive sleep apnoeas based on the known criteria. HR comparison was evaluated against estimates attained from an electrocardiogram (ECG). Novametrix differed from ECG by 0.71 ± 0.58% (p < 0.05) while Masimo differed by 4.51 ± 3.66% (p > 0.05). Modern oximeters can be attractive for their improved SaO2 measurement. However, using raw PPG signals obtained directly from these oximeters for timing-related measurements warrants further investigations.


PACS

87.63.L- Visual imaging

87.19.U- Hemodynamics

87.19.Hh Cardiac dynamics

47.63.Cb Blood flow in cardiovascular system

87.80.-y Biophysical techniques (research methods)

Subjects

Fluid dynamics

Instrumentation and measurement

Biological physics

Medical physics

Dates

Issue 4 (August 2005)

Received 3 February 2005, accepted for publication 22 April 2005

Published 10 May 2005



  1. Variability in time delay between two models of pulse oximeters for deriving the photoplethysmographic signals

    Jong Yong A Foo et al 2005 Physiol. Meas. 26 531

  2. XAFS studies of Pt nanoparticles deposition on Si nanowires

    Lijia Liu et al 2009 J. Phys.: Conf. Ser. 190 012133

  3. Photodetachment from negative ions in the static electric field: effect of strong electromagnetic field

    V N Ostrovsky and D A Telnov 1993 J. Phys. B: At. Mol. Opt. Phys. 26 415

  4. A taste sensor

    Kiyoshi Toko 1998 Meas. Sci. Technol. 9 1919

  5. Eliminating mechanical perturbations in scanning probe microscopy

    G Schitter and A Stemmer 2002 Nanotechnology 13 663

  6. Auxiliary matrices on both sides of the equator

    Christian Korff 2005 J. Phys. A: Math. Gen. 38 47

  7. Transport simulations of the ignited ITER with high helium fraction

    G. Becker 1994 Nucl. Fusion 34 507

  8. Direct inner-shell ionization of atomic ions by electron impact

    V I Fisher et al 2006 Phys. Scr. 74 614

  9. Calculation of the uncertainty of the mean of autocorrelated measurements

    Nien Fan Zhang 2006 Metrologia 43 S276

  10. An amateur video camera as a detector of infrared radiation

    Zdeněk Bochníček 2008 Phys. Educ. 43 51

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.