R Kumazawa et al 2003 Plasma Phys. Control. Fusion 45 1037 doi:10.1088/0741-3335/45/6/315
R Kumazawa1, K Saito1, Y Torii2, T Mutoh1, T Seki1, T Watari1, M Osakabe1, S Murakami1, M Sasao3, T Watanabe1, T Yamamoto2, T Notake2, N Takeuchi2, T Saida4, F Shimpo1, G Nomura1, M Yokota1, A Kato1, Y Zao5, H Okada6, M Isobe1, T Ozaki1, K Narihara1, Y Nagayama1, S Inagaki1, S Morita1, A V Krasilnikov7, H Idei1, S Kubo1, K Ohkubo1, M Sato1, T Shimozuma1, Y Yoshimura1, K Ikeda1, K Nagaoka1, Y Oka1, Y Takeiri1, K Tsumori1, N Ashikawa1, M Emoto1, H Funaba1, M Goto1, K Ida1, T Kobuchi1, Y Liang5, S Masuzaki1, T Minami1, J Miyazawa1, T Morisaki1, S Muto1, Y Nakamura1, H Nakanishi1, K Nishimura1, N Noda1, S Ohdachi1, B J Peterson1, A Sagara1, S Sakakibara1, R Sakamoto1, K Sato1, M Shoji1, H Suzuki1, K Tanaka1, K Toi1, T Tokuzawa1, K Y Watanabe1, I Yamada1, S Yamamoto2, M Yoshinuma1, M Yokoyama1, K-Y Watanabe1, O Kaneko1, K Kawahata1, A Komori1, N Ohyabu1, H Yamada1, K Yamazaki1, S Sudo1, K Matsuoka1, Y Hamada1, O Motojima1, M Fujiwara1 and the LHD Experimental Group
Show affiliationsThe behaviour of high-energy ions accelerated by an ion cyclotron range of frequency (ICRF) electric field in the large helical device (LHD) is discussed. A better confinement performance of high-energy ions in the inward-shifted magnetic axis configuration was experimentally verified by measuring their energy spectrum and comparing it with the effective temperature determined by an electron slowing down process. In the standard magnetic axis configuration a saturation of the measured tail temperature was observed as the effective temperature was increased. The ratio between these two quantities is a measure of the quality of transfer efficiency from high-energy ions to a bulk plasma; when this efficiency was compared with Monte Carlo simulations the results agreed fairly well.
The ratio of the stored energy of the high-energy ions to that of the bulk plasma was measured using an ICRF heating power modulation method; it was deduced from phase differences between total and bulk plasma stored energies and the modulated ICRF heating power. The measured high energy fraction agreed with that calculated using the injected ICRF heating power, the transfer efficiency determined in the experiment and the confinement scaling of the LHD plasma.
52.50.Qt Plasma heating by radio-frequency fields; ICR, ICP, helicons
Issue 6 (June 2003)
Received 14 February 2003
Published 27 May 2003
R Kumazawa et al 2003 Plasma Phys. Control. Fusion 45 1037
B P Abbott et al 2009 Rep. Prog. Phys. 72 076901
Maximo Bañados et al JHEP05(2004)039
Byoung-Kye Kim et al 2005 Nanotechnology 16 1177
H Horner and H Wagner 1974 J. Phys. C: Solid State Phys. 7 3305
Chieh Chang et al 2005 J. Micromech. Microeng. 15 812
JoAnne L. Hewett and Thomas G. Rizzo JHEP12(2007)009
Shou Hua Zhu 1998 J. Phys. G: Nucl. Part. Phys. 24 1703
Priyadarshi Panda et al 2009 New J. Phys. 11 115001
T H C Childs and G W Rowe 1973 Rep. Prog. Phys. 36 223