Performance of a Carnot refrigerator at maximum cooling power

D C Agrawal and V J Menon

Show affiliations


The optimization procedure of finite-time thermodynamics is extended in order to calculate the coefficient of performance of ideal refrigerators at maximum cooling power. For this purpose, the cycle time has to be altered somewhat to allow for the occurrence of adiabatic arms in the cycle.


PACS

07.20.Mc Cryogenics; refrigerators, low-temperature equipment

05.70.-a Thermodynamics

MSC

82B30 Statistical thermodynamics (See also 80-XX)

Subjects

Instrumentation and measurement

Statistical physics and nonlinear systems

Dates

Issue 22 (21 November 1990)



Users also read

What's this?
This innovative new feature generates a list of articles 'also read' by other users based on them reading the original article. Article abstracts citations and references are all considered and weighted accordingly. We hope that this will help you find relevant papers for your research.