Quick search Find article
Quick search
Find article

Characterization of a novel phantom for three-dimensional in vitro cell experiments

Michael B Altman1, Benjamin J Vesper2,3, Brett D Smith4, Michelle A Stinauer4, Charles A Pelizzari1, Bulent Aydogan1,4, Chester S Reft1, James A Radosevich2,3, Steven J Chmura1 and John C Roeske5

Show affiliations


NOTE

A novel intensity-modulated radiation therapy (IMRT) phantom for use in three-dimensional in vitro cell experiments, based on a commercially available system (CIRS Inc., Norfolk, VA), was designed and fabricated. The water-equivalent plastic phantom can, with a set of water-equivalent plastic inserts, enclose 1–3 multi-well tissue culture plates. Dosimetry within the phantom was assessed using thermoluminescence dosimeters (TLDs) and film. The phantom was loaded with three tissue culture plates, and an array of TLDs or a set of three films was placed underneath each plate within the phantom, and then irradiated using an IMRT plan created for it. Measured doses from each dosimeter were compared to those acquired from the treatment planning system. The percent differences between TLD measurements and the corresponding points in the treatment plan ranged from 1.3% to 2.9%, differences which did not show statistical significance. Average point-by-point percent dose differences for each film plane ranged from 1.6% to 3.1%. The percentage dose difference for which 95% of the points in the film matched those corresponding to the calculated dose plane to within 3.0% ranged from 2.8% to 4.2%. The good agreement between predicted and measured dose shows that the phantom is a useful and efficient tool for three-dimensional in vitro cell experiments.


PACS

87.50.wj Dosimetry/exposure assessment

87.56.Da Ancillary equipment

87.17.-d Cell processes

87.56.ng Wedges and compensators

87.55.-x Treatment strategy

Subjects

Medical physics

Biological physics

Dates

Issue 5 (7 March 2009)

Received 16 September 2008, in final form 10 December 2008

Published 30 January 2009



  1. Characterization of a novel phantom for three-dimensional in vitro cell experiments

    Michael B Altman et al 2009 Phys. Med. Biol. 54 N75

  2. `Atoms in Molecules': A Simple Approach

    E Theal Stewart 1960 Proc. Phys. Soc. 75 402

  3. Invariant and partially-invariant solutions of the equations describing a non-stationary and isentropic flow for an ideal and compressible fluid in (3 + 1) dimensions

    A M Grundland and L Lalague 1996 J. Phys. A: Math. Gen. 29 1723

  4. Measurement of the gravitational red shift with the Mössbauer effect

    T E Cranshaw and J P Schiffer 1964 Proc. Phys. Soc. 84 245

  5. Fibre Bragg grating photowriting in microstructured optical fibres for refractive index measurement

    M C Phan Huy et al 2006 Meas. Sci. Technol. 17 992

  6. Development and successful testing of MCP BSCCO-2212 components for a 10 MVA resistive superconducting fault current limiter

    J Bock et al 2004 Supercond. Sci. Technol. 17 S122

  7. Nonlinear System Identification

    Oliver Nelles 2002 Meas. Sci. Technol. 13 646

  8. Electronic correlation effects in transition-metal sulfides

    A Rohrbach et al 2003 J. Phys.: Condens. Matter 15 979

  9. Riccati equations and convolution formulae for functions of Rayleigh type

    Dharma P Gupta and Martin E Muldoon 2000 J. Phys. A: Math. Gen. 33 1363

  10. Electronic structure of defects and impurities in a-Si

    B K Agrawal et al 1990 J. Phys.: Condens. Matter 2 6519

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.