Computerized detection of diffuse lung disease in MDCT: the usefulness of statistical texture features

Jiahui Wang1, Feng Li2, Kunio Doi2 and Qiang Li1,3

Show affiliations


Accurate detection of diffuse lung disease is an important step for computerized diagnosis and quantification of this disease. It is also a difficult clinical task for radiologists. We developed a computerized scheme to assist radiologists in the detection of diffuse lung disease in multi-detector computed tomography (CT). Two radiologists selected 31 normal and 37 abnormal CT scans with ground glass opacity, reticular, honeycombing and nodular disease patterns based on clinical reports. The abnormal cases in our database must contain at least an abnormal area with a severity of moderate or severe level that was subjectively rated by the radiologists. Because statistical texture features may lack the power to distinguish a nodular pattern from a normal pattern, the abnormal cases that contain only a nodular pattern were excluded. The areas that included specific abnormal patterns in the selected CT images were then delineated as reference standards by an expert chest radiologist. The lungs were first segmented in each slice by use of a thresholding technique, and then divided into contiguous volumes of interest (VOIs) with a 64 × 64 × 64 matrix size. For each VOI, we determined and employed statistical texture features, such as run-length and co-occurrence matrix features, to distinguish abnormal from normal lung parenchyma. In particular, we developed new run-length texture features with clear physical meanings to considerably improve the accuracy of our detection scheme. A quadratic classifier was employed for distinguishing between normal and abnormal VOIs by the use of a leave-one-case-out validation scheme. A rule-based criterion was employed to further determine whether a case was normal or abnormal. We investigated the impact of new and conventional texture features, VOI size and the dimensionality for regions of interest on detecting diffuse lung disease. When we employed new texture features for 3D VOIs of 64 × 64 × 64 voxels, our system achieved the highest performance level: a sensitivity of 86% and a specificity of 90% for the detection of abnormal VOIs, and a sensitivity of 89% and a specificity of 90% for the detection of abnormal cases. Our computerized scheme would be useful for assisting radiologists in the diagnosis of diffuse lung disease.


PACS

87.59.bd Computed radiography

87.57.R- Computer-aided diagnosis

87.57.C- Image quality

87.19.X- Diseases

87.57.N- Image analysis

Subjects

Biological physics

Medical physics

Dates

Issue 22 (21 November 2009)

Received 3 June 2009, in final form 2 October 2009

Published 28 October 2009



  1. Computerized detection of diffuse lung disease in MDCT: the usefulness of statistical texture features

    Jiahui Wang et al 2009 Phys. Med. Biol. 54 6881

  2. The LISA verification binaries

    A Stroeer and A Vecchio 2006 Class. Quantum Grav. 23 S809

  3. On the geometric approach to the motion of inertial mechanical systems

    Adrian Constantin and Boris Kolev 2002 J. Phys. A: Math. Gen. 35 R51

  4. Perturbation theory for the nonlinear Schrödinger equation with a random potential

    Shmuel Fishman et al 2009 Nonlinearity 22 2861

  5. Analysis of skin tissues spatial fluorescence distribution by the Monte Carlo simulation

    D Y Churmakov et al 2003 J. Phys. D: Appl. Phys. 36 1722

  6. The asymptotic distributions of the size of the largest length of a reversible Markov process of polymerization

    Dong Han 2003 J. Phys. A: Math. Gen. 36 7485

  7. Exact Bianchi identity in Regge gravity

    Herbert W Hamber and Geoff Kagel 2004 Class. Quantum Grav. 21 5915

  8. Hamiltonian analysis of Plebanski theory

    E Buffenoir et al 2004 Class. Quantum Grav. 21 5203

  9. Higher-dimensional extensions of Pauli spin matrices

    J F Stephany 1979 J. Phys. A: Math. Gen. 12 1667

  10. Characterization of Photofrin photobleaching for singlet oxygen dose estimation during photodynamic therapy of MLL cells in vitro

    Jonathan S Dysart and Michael S Patterson 2005 Phys. Med. Biol. 50 2597

Related review articles

What's this?
View review articles related to this research to gain an insight into the key trends in this subject area. Related review articles are selected based on PACS/MSC codes, and are no more than three years old.

  1. Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction?

View by subject




Export






Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.