Raphaël Serduc et al 2009 Phys. Med. Biol. 54 6711 doi:10.1088/0031-9155/54/21/017
Raphaël Serduc1,2, Audrey Bouchet3, Elke Bräuer-Krisch3, Jean A Laissue4, Jenny Spiga5, Sukhéna Sarun3, Alberto Bravin3, Caroline Fonta1,2, Luc Renaud1,2, Jean Boutonnat6, Erik Albert Siegbahn7, François Estève8 and Géraldine Le Duc3
Show affiliationsTo analyze the effects of the microbeam width (25, 50 and 75 µm) on the survival of 9L gliosarcoma tumor-bearing rats and on toxicity in normal tissues in normal rats after microbeam radiation therapy (MRT), 9L gliosarcomas implanted in rat brains, as well as in normal rat brains, were irradiated in the MRT mode. Three configurations (MRT25, MRT50, MRT75), each using two orthogonally intersecting arrays of either 25, 50 or 75 µm wide microbeams, all spaced 211 µm on center, were tested. For each configuration, peak entrance doses of 860, 480 and 320 Gy, respectively, were calculated to produce an identical valley dose of 18 Gy per individual array at the center of the tumor. Two, 7 and 14 days after radiation treatment, 42 rats were killed to evaluate histopathologically the extent of tumor necrosis, and the presence of proliferating tumors cells and tumor vessels. The median survival times of the normal rats were 4.5, 68 and 48 days for MRT25, 50 and 75, respectively. The combination of the highest entrance doses (860 Gy per array) with 25 µm wide beams (MRT25) resulted in a cumulative valley dose of 36 Gy and was excessively toxic, as it led to early death of all normal rats and of ~50% of tumor-bearing rats. The short survival times, particularly of rats in the MRT25 group, restricted adequate observance of the therapeutic effect of the method on tumor-bearing rats. However, microbeams of 50 µm width led to the best median survival time after 9L gliosarcoma MRT treatment and appeared as the better compromise between tumor control and normal brain toxicity compared with 75 µm or 25 µm widths when used with a 211 µm on-center distance. Despite very high radiation doses, the tumors were not sterilized; viable proliferating tumor cells remained present at the tumor margin. This study shows that microbeam width and peak entrance doses strongly influence tumor responses and normal brain toxicity, even if valley doses are kept constant in all groups. The use of 50 µm wide microbeams combined with moderate peak doses resulted in a higher therapeutic ratio.
Issue 21 (7 November 2009)
Received 8 March 2009, in final form 15 September 2009
Published 20 October 2009
Raphaël Serduc et al 2009 Phys. Med. Biol. 54 6711
Chris Wainwright and Ruth M Williams 2004 Class. Quantum Grav. 21 4865
M Kohandel et al 2007 Phys. Med. Biol. 52 3665
Ole G Mouritsen et al 2006 J. Phys.: Condens. Matter 18 S1293
C Vignal et al 2008 Phys. Med. Biol. 53 2457
Lin Yan et al. 2005 ApJ 628 604
Naomi Hirano et al 2004 ApJ 616 L43
K Niinimäki et al 2007 Phys. Med. Biol. 52 6663
S Redner 1985 J. Phys. A: Math. Gen. 18 L723
Sun Yan et al 1988 J. Phys. D: Appl. Phys. 21 1706