Yongfeng Yang et al 2009 Phys. Med. Biol. 54 433 doi:10.1088/0031-9155/54/2/017
Yongfeng Yang1, Jinyi Qi1, Yibao Wu1, Sara St James1, Richard Farrell2, Purushottam A Dokhale2, Kanai S Shah2 and Simon R Cherry1
Show affiliationsMany laboratories develop depth-encoding detectors to improve the trade-off between spatial resolution and sensitivity in positron emission tomography (PET) scanners. One challenge in implementing these detectors is the need to calibrate the depth of interaction (DOI) response for the large numbers of detector elements in a scanner. In this work, we evaluate two different methods, a linear detector calibration and a linear crystal calibration, for determining DOI calibration parameters. Both methods can use measurements from any source distribution and location, or even the intrinsic lutetium oxyorthosilicate (LSO) background activity, and are therefore well suited for use in a depth-encoding PET scanner. The methods were evaluated by measuring detector and crystal DOI responses for all eight detectors in a prototype depth-encoding PET scanner. The detectors utilize dual-ended readout of LSO scintillator arrays with position-sensitive avalanche photodiodes (PSAPDs). The LSO arrays have 7 × 7 elements, with a crystal size of 0.92 × 0.92 × 20 mm3 and pitch of 1.0 mm. The arrays are read out by two 8 × 8 mm2 area PSAPDs placed at opposite ends of the arrays. DOI is measured by the ratio of the amplitude of the total energy signals measured by the two PSAPDs. Small variations were observed in the DOI responses of different crystals within an array as well as DOI responses for different arrays. A slightly nonlinear dependence of the DOI ratio on depth was observed and the nonlinearity was larger for the corner and edge crystals. The DOI calibration parameters were obtained from the DOI responses measured in a singles mode. The average error between the calibrated DOI and the known DOI was 0.8 mm if a linear detector DOI calibration was used and 0.5 mm if a linear crystal DOI calibration was used. A line source phantom and a hot rod phantom were scanned on the prototype PET scanner. DOI measurement significantly improved the image spatial resolution no matter which DOI calibration method was used. A linear crystal DOI calibration provided slightly better image spatial resolution compared with a linear detector DOI calibration.
87.57.uk Positron emission tomography (PET)
Issue 2 (21 January 2009)
Received 8 September 2008, in final form 24 November 2008
Published 19 December 2008
Yongfeng Yang et al 2009 Phys. Med. Biol. 54 433
Steve Croft et al. 2008 The Astronomical Journal 135 1793
Cormac Reynolds et al. 2009 ApJ 706 851
A R Bishop 2008 J. Phys.: Conf. Ser. 108 012027
E. Panko et al. 2009 The Astronomical Journal 138 1709
D. M. Townsley et al. 2007 ApJ 668 1118
E. S. Voges et al. 2008 The Astronomical Journal 135 1291
Neil Lambert and Paul Richmond JHEP10(2009)084
E A Parson 2008 Environ. Res. Lett. 3 045016
Jonah Busch et al 2009 Environ. Res. Lett. 4 044006