Some considerations concerning volume-modulated arc therapy: a stepping stone towards a general theory

FEATURED ARTICLE

S Webb and D McQuaid

Show affiliations


In this paper it is formally shown that the dynamic multileaf collimator (MLC) IMRT delivery technique remains valid if the MLC is supported on a 1D moving platform. It is also shown that, in such circumstances, it is always time preferable to deliver overlapping modulating fields as a single swept field rather than as separate fields. The most general formulism is presented and then related to simpler equations in limiting cases. The paper explains in detail how a 'small-arc approximation' can be invoked to relate the 1D linear theory to the MLC-on-moving-platform-(gantry) delivery technique involving rotation therapy and known as volume-modulated arc therapy (VMAT). It is explained how volume-modulated arc therapy delivered with open unmodulated fields and which can deliver conformal dose distributions can be interpreted as an IMRT delivery. The (Elekta adopted) term VMAT will be used in a generic sense to include a similar (Varian) method known as RapidArc. Approximate expressions are derived for the 'amount of modulation' possible in a VMAT delivery. This paper does not discuss the actual VMAT planning but gives an insight at a deep level into VMAT delivery. No universal theory of VMAT is known in the sense that there is no theory that can predict precisely the performance of a VMAT delivery in terms of the free parameters available (variable gantry speed, variable fluence-delivery rate, set of MLC shapes, MLC orientation, number of arcs, coplanarity versus non-coplanarity, etc). This is in stark contrast to the situation with several other IMRT delivery techniques where such theoretical analyses are known. In this paper we do not provide such a theory; the material presented is a stepping stone on the path towards this.


 

General scientific summary. No complete general theory of the intensity-modulated radiotherapy (IMRT) technique known as volumetric arc therapy (VMAT) (or RapidArc) yet exists. We believe obtaining this will be very difficult given the complex interactions between the variables of the problem. The purpose of this paper is to present some 'stepping stone' analyses that help an understanding of VMAT and also to highlight outstanding problems for ongoing study. It is shown that the theory of the dynamic multileaf collimator IMRT technique remains valid when the MLC is on a carriage that moves in the same 1D direction as the MLC leaves. A small-arc approximation is introduced, thoroughly analysed and used to explain how VMAT can be related to this. Following this, the theory allows an insight into 'how much fluence modulation' is possible with VMAT knowing the parameters of the delivery. Another analysis gives a hint to why VMAT is temporally efficient. That VMAT can be considered an IMRT technique is explained in terms of re-arranging the unmodulated VMAT fan beams into equivalent modulated parallel beams.

PACS

87.53.Kn Conformal radiation treatment

87.55.-x Treatment strategy

87.56.J- Collimation

87.53.Bn Dosimetry/exposure assessment

Subjects

Medical physics

Dates

Issue 14 (21 July 2009)

Received 25 February 2009, in final form 19 May 2009

Published 23 June 2009



  1. Some considerations concerning volume-modulated arc therapy: a stepping stone towards a general theory

    S Webb and D McQuaid 2009 Phys. Med. Biol. 54 4345

  2. Reply to 'Comments on 'Single-Arc IMRT?''

    Thomas Bortfeld and Steve Webb 2009 Phys. Med. Biol. 54 L35

  3. Reply to 'Letter to the Editor on 'Single-Arc IMRT?''

    Thomas Bortfeld and Steve Webb 2009 Phys. Med. Biol. 54 L43

  4. Letter to the Editor on 'Single-Arc IMRT?'

    Karl Otto 2009 Phys. Med. Biol. 54 L37

  5. Single-Arc IMRT?

    Thomas Bortfeld and Steve Webb 2009 Phys. Med. Biol. 54 N9

  6. Intensity-modulated arc therapy with dynamic multileaf collimation: an alternative to tomotherapy

    C X Yu 1995 Phys. Med. Biol. 40 1435

  7. Comments on 'Single-Arc IMRT?'

    W F A R Verbakel et al 2009 Phys. Med. Biol. 54 L31

  8. GATE: a simulation toolkit for PET and SPECT

    S Jan et al 2004 Phys. Med. Biol. 49 4543

  9. On Academician E K Zavoisky's centenary

    A V Kessenikh 2007 Phys.-Usp. 50 977

  10. Fabrication of biomolecule–copolymer hybrid nanovesicles as energy conversion systems

    Dean Ho et al 2005 Nanotechnology 16 3120

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.