CALDose_X—a software tool for the assessment of organ and tissue absorbed doses, effective dose and cancer risks in diagnostic radiology

FEATURED ARTICLE

R Kramer1, H J Khoury1 and J W Vieira2,3

Show affiliations


CALDose_X is a software tool that provides the possibility of calculating incident air kerma (INAK) and entrance surface air kerma (ESAK), two important quantities used in x-ray diagnosis, based on the output of the x-ray equipment. Additionally, the software uses conversion coefficients (CCs) to assess the absorbed dose to organs and tissues of the human body, the effective dose as well as the patient's cancer risk for radiographic examinations. The CCs, ratios between organ or tissue absorbed doses and measurable quantities, have been calculated with the FAX06 and the MAX06 phantoms for 34 projections of 10 commonly performed x-ray examinations, for 40 combinations of tube potential and filtration ranging from 50 to 120 kVcp and from 2.0 to 5.0 mm aluminum, respectively, for various field positions, for 29 selected organs and tissues and simultaneously for the measurable quantities, INAK, ESAK and kerma area product (KAP). Based on the x-ray irradiation parameters defined by the user, CALDose_X shows images of the phantom together with the position of the x-ray beam. By using true to nature voxel phantoms, CALDose_X improves earlier software tools, which were mostly based on mathematical MIRD5-type phantoms, by using a less representative human anatomy.


 

For more information on this article, see medicalphysicsweb.org

PACS

87.59.B- Radiography

87.56.Da Ancillary equipment

87.55.N- Radiation monitoring, control, and safety

87.19.X- Diseases

Subjects

Biological physics

Medical physics

Dates

Issue 22 (21 November 2008)

Received 30 June 2008, in final form 29 September 2008

Published 21 October 2008



  1. CALDose_X—a software tool for the assessment of organ and tissue absorbed doses, effective dose and cancer risks in diagnostic radiology

    R Kramer et al 2008 Phys. Med. Biol. 53 6437

  2. Renormalization group calculation for the reaction kA to OE

    B P Lee 1994 J. Phys. A: Math. Gen. 27 2633

  3. Racing Academy

    Jim Turner et al 2004 Phys. Educ. 39 429

  4. Carbon nanotube biocompatibility with cardiac muscle cells

    Silvano Garibaldi et al 2006 Nanotechnology 17 391

  5. Frequency Stability of Atomic Clocks Based on Coherent Population Trapping Resonance in 85Rb

    Liu Lu et al 2007 Chinese Phys. Lett. 24 1883

  6. Observation of turbulent-driven shear flow in a cylindrical laboratory plasma device

    G R Tynan et al 2006 Plasma Phys. Control. Fusion 48 S51

  7. The kew radio sonde

    E G Dymond 1947 Proc. Phys. Soc. 59 645

  8. Symmetry breaking in few layer graphene films

    Aaron Bostwick et al 2007 New J. Phys. 9 385

  9. The rehybridization of electronic orbitals in carbon nanotubes

    Ouyang Yu et al 2008 Chinese Phys. B 17 3123

  10. Thermal properties of paratellurite (TeO2) at low temperatures

    G K White et al 1990 J. Phys.: Condens. Matter 2 7715

Related review articles

What's this?
View review articles related to this research to gain an insight into the key trends in this subject area. Related review articles are selected based on PACS/MSC codes, and are no more than three years old.

  1. Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction?

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.