Technical note: comparing coherent and incoherent scatter effects for cone-beam CT

Yiannis Kyriakou, Michael Meyer and Willi A Kalender

Show affiliations


NOTE

The intensity and distribution of scatter is of growing interest in the case of flat-detector CT (FD-CT) scanners. It is generally assumed that scatter is an offset distribution dominated by incoherent scatter (Compton effect). Coherent and incoherent scatter were computed with respect to acquisition parameters used in FD-CT. A hybrid method optimized the performance of the scatter simulation: a fast and exact analytical calculation of the single-scatter intensity combined with a coarse Monte Carlo (MC) estimate of multiple scatter to reduce overall computational expenses, while assuring an acceptable signal quality. The simulation package allowed for the separation of both coherent and incoherent single scatter. For cylindrical water phantoms varying from 40 mm to 320 mm diameter and for various z-collimations an investigation of the ratio of single-to-total scatter was performed. The intensity distribution of scatter (including coherent single scatter, incoherent single scatter and total scatter) was computed for phantoms of 160 mm and 320 mm diameter and energies varying from 40 keV to 120 keV. Additionally, voxel phantoms were generated from clinical head and thorax CT datasets and were employed in scatter simulations to demonstrate the effect of coherent and incoherent single scatter on the 2D projections. Single scatter determines a significant fraction of total scatter even for large body-sized phantoms and large field of measurement. Coherent scatter dominates the distribution of total scatter for most of the simulated cases, even for 120 keV. The Compton effect appeared to be less influential with respect to spatial distribution but dominated the overall magnitude.


PACS

87.59.bd Computed radiography

87.63.-d Non-ionizing radiation equipment and techniques

87.57.N- Image analysis

87.57.C- Image quality

Subjects

Medical physics

Dates

Issue 10 (21 May 2008)

Received 12 February 2008, in final form 18 March 2008

Published 25 April 2008



  1. Technical note: comparing coherent and incoherent scatter effects for cone-beam CT

    Yiannis Kyriakou et al 2008 Phys. Med. Biol. 53 N175

  2. Size effect on gas flow in micro nozzles

    Peng-Fei Hao et al 2005 J. Micromech. Microeng. 15 2069

  3. Metallicities and Physical Conditions in Star-forming Galaxies at z ~ 1.0-1.5

    Xin Liu et al. 2008 ApJ 678 758

  4. The Treatment of Non-LTE Line Blanketing in Spherically Expanding Outflows

    D. John Hillier and D. L. Miller 1998 ApJ 496 407

  5. Perfect fluid theory and its extensions

    R Jackiw et al 2004 J. Phys. A: Math. Gen. 37 R327

  6. Modeling and simulations of thermoelastic damping in microplates

    Ali H Nayfeh and Mohammad I Younis 2004 J. Micromech. Microeng. 14 1711

  7. Biodegradable nanoparticles for targeted ultrasound imaging of breast cancer cells in vitro

    Jun Liu et al 2007 Phys. Med. Biol. 52 4739

  8. The influence of electronic structure on hydrogen absorption in palladium alloys

    Xuezhi Ke et al 2004 J. Phys.: Condens. Matter 16 6267

  9. A New Photometric Technique for the Joint Selection of Star-forming and Passive Galaxies at 1.4 z 2.5

    E. Daddi et al. 2004 ApJ 617 746

  10. Probing the Shape of the Galactic Halo with Hypervelocity Stars

    Oleg Y. Gnedin et al. 2005 ApJ 634 344

Related review articles

What's this?
View review articles related to this research to gain an insight into the key trends in this subject area. Related review articles are selected based on PACS/MSC codes, and are no more than three years old.

  1. Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction?

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.