Statistical reconstruction for x-ray computed tomography using energy-integrating detectors

Giovanni M Lasio1, Bruce R Whiting2 and Jeffrey F Williamson1

Show affiliations


Statistical image reconstruction (SR) algorithms have the potential to significantly reduce x-ray CT image artefacts because they use a more accurate model than conventional filtered backprojection and can incorporate effects such as noise, incomplete data and nonlinear detector response. Most SR algorithms assume that the CT detectors are photon-counting devices and generate Poisson-distributed signals. However, actual CT detectors integrate energy from the x-ray beam and exhibit compound Poisson-distributed signal statistics. This study presents the first assessment of the impact on image quality of the resultant mismatch between the detector and signal statistics models assumed by the sinogram data model and the reconstruction algorithm. A 2D CT projection simulator was created to generate synthetic polyenergetic transmission data assuming (i) photon-counting with simple Poisson-distributed signals and (ii) energy-weighted detection with compound Poisson-distributed signals. An alternating minimization (AM) algorithm was used to reconstruct images from the data models (i) and (ii) for a typical abdominal scan protocol with incident particle fluence levels ranging from 105 to 1.6 × 106 photons/detector. The images reconstructed from data models (i) and (ii) were compared by visual inspection and image-quality figures of merit. The reconstructed image quality degraded significantly when the means were mismatched from the assumed model. However, if the signal means are appropriately modified, images from data models (i) and (ii) did not differ significantly even when SNR is very low. While data-mean mismatches characteristic of the difference between particle-fluence and energy-fluence transmission can cause significant streaking and cupping artefacts, the mismatch between the actual and assumed CT detector signal statistics did not significantly degrade image quality once systematic data means mismatches were corrected.


PACS

87.59.bd Computed radiography

02.50.Ng Distribution theory and Monte Carlo studies

87.57.C- Image quality

87.57.N- Image analysis

Subjects

Computational physics

Medical physics

Dates

Issue 8 (21 April 2007)

Received 4 October 2006, in final form 15 February 2007

Published 2 April 2007



Users also read

What's this?
This innovative new feature generates a list of articles 'also read' by other users based on them reading the original article. Article abstracts citations and references are all considered and weighted accordingly. We hope that this will help you find relevant papers for your research.

  1. The design of an optical sensor arrangement for the detection of oil contamination in an adhesively bonded structure of a liquefied natural gas (LNG) ship
  2. Fluctuation theorems for stochastic dynamics
  3. Phenomena of liquid drop impact on solid and liquid surfaces
More

Related review articles

What's this?
View review articles related to this research to gain an insight into the key trends in this subject area. Related review articles are selected based on PACS/MSC codes, and are no more than three years old.

  1. Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction?

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.