Yongbok Kim et al 2007 Phys. Med. Biol. 52 2147 doi:10.1088/0031-9155/52/8/007
Yongbok Kim, Lynn J Verhey and Ping Xia
Show affiliationsThe aim of this study is to investigate the feasibility of using conventional jaws to deliver inverse planned intensity-modulated radiotherapy (IMRT) plans for patients with prostate cancer. For ten patients, each had one three-dimensional conformal plan (3D plan) and seven inverse IMRT plans using direct aperture optimization. For IMRT plans using conventional jaws (JO plans), the number of apertures per beam angle was set from two to seven while three apertures per beam angle were set for the multi-leaf collimator (MLC) plans. To evaluate each planning method, we compared average dose volume histograms (DVH), the conformal index (COIN), total number of segments and total number of monitor units. Among the JO plans with the number of apertures per beam angle varying from two to seven, no difference was observed in the average DVHs, and the plan conformal index became saturated after four apertures per beam angle. Subsequently, JO plans with four apertures per beam angle (JO-4A) were compared with 3D and MLC plans. Based on the average DVHs, no difference was found among 3D, JO-4A and MLC plans with regard to the planning target volume and rectum, but the DVHs for the bladder and penile bulb were significantly better with inverse IMRT plans than those with 3D plans. When compared with the plan conformity, the average COIN values for 3D, JO-4A and MLC plans were 0.61 ± 0.07, 0.73 ± 0.05 and 0.83 ± 0.05, respectively. In conclusion, inverse IMRT plans using conventional jaws are clinically feasible, achieving better plan quality than 3D-CRT plans.
Issue 8 (21 April 2007)
Received 11 December 2006, in final form 1 February 2007
Published 27 March 2007
Yongbok Kim et al 2007 Phys. Med. Biol. 52 2147
V Pravda et al 2007 Class. Quantum Grav. 24 1691
L Galleani and P Tavella 2003 Metrologia 40 S326
Z Jiang 2008 Metrologia 45 S6
Richard Bamler and Philipp Hartl 1998 Inverse Problems 14 R1
R Sturgeon and R Wahlen 2002 Metrologia 39 08003
C L Cheung et al 2006 Nanotechnology 17 1339
J M Alison and R M Hill 1994 J. Phys. D: Appl. Phys. 27 1291
Rajesh Das and Swati Ray 2003 J. Phys. D: Appl. Phys. 36 152
Filipe Moura and Ricardo Schiappa 2007 Class. Quantum Grav. 24 361