H S Sakhalkar et al 2007 Phys. Med. Biol. 52 2035 doi:10.1088/0031-9155/52/8/001
H S Sakhalkar1, M Dewhirst1, T Oliver2, Y Cao1 and M Oldham3
Show affiliationsOptical emission computed tomography (optical-ECT) is a technique for imaging the three-dimensional (3D) distribution of fluorescent probes in biological tissue specimens with high contrast and spatial resolution. In optical-ECT, functional information can be imaged by (i) systemic application of functional labels (e.g. fluorophore labelled proteins) and/or (ii) endogenous expression of fluorescent reporter proteins (e.g. red fluorescent protein (RFP), green fluorescent protein (GFP)) in vivo. An essential prerequisite for optical-ECT is optical clearing, a procedure where tissue specimens are made transparent to light by sequential perfusion with fixing, dehydrating and clearing agents. In this study, we investigate clearing protocols involving a selection of common fixing (4% buffered paraformaldehyde (PFA), methanol and ethanol), dehydrating (methanol and ethanol) and clearing agents (methyl salicylate and benzyl-alcohol-benzyl-benzoate (BABB)) in order to determine a 'fluorescence friendly' clearing procedure. Cell culture experiments were employed to optimize the sequence of chemical treatments that best preserve fluorescence. Texas red (TxRed), fluorescein isothiocyanate (FITC), RFP and GFP were tested as fluorophores and fluorescent reporter proteins of interest. Fluorescent and control cells were imaged on a microscope using a DSred2 and FITC filter set. The most promising clearing protocols of cell culture experiments were applied to whole xenograft tumour specimens, to test their effectiveness in large unsectioned samples. Fluorescence of TxRed/FITC fluorophores was not found to be significantly affected by any of the test clearing protocols. RFP and GFP fluorescence, however, was found to be significantly greater when cell fixation was in ethanol. Fixation in either PFA or methanol resulted in diminished fluorescence. After ethanol fixation, the RFP and GFP fluorescence proved remarkably robust to subsequent exposure to either methyl salicylate or BABB. The optimized optical clearing procedure of ethanol fixation followed by methyl salicylate clearing preserved the fluorescence of constitutive RFP in whole xenograft tumour specimens, about 1 cc in dimension, indicating successful extension from cell plating experiments to whole tissue samples. Finally, the feasibility of imaging the 3D distribution of viable tumour cells (as indicated by the RFP emission) is demonstrated by optical-ECT imaging of cleared xenograft tumours using an in-house system.
For more information on this article, see medicalphysicsweb.org
Issue 8 (21 April 2007)
Received 11 December 2006, in final form 1 February 2007
Published 20 March 2007
H S Sakhalkar et al 2007 Phys. Med. Biol. 52 2035
Christopher Kohler 2003 J. Phys.: Condens. Matter 15 133
Igor D Kaganovich et al 2006 New J. Phys. 8 278
Chopin Soo 2002 Class. Quantum Grav. 19 1051
S Emura et al 2009 J. Phys.: Conf. Ser. 190 012102
R Atkinson and G A Jones 1976 J. Phys. D: Appl. Phys. 9 L131
Li Zhi and Han Chong-Zhao 2002 Chinese Phys. 11 666
Y Yamada et al 2006 Metrologia 43 L23
G Beutier et al 2009 New J. Phys. 11 113026
Helena Maier-Metz 1998 Eur. J. Phys. 19 137