Pixel-by-pixel deconvolution of bolus-tracking data: optimization and implementation

S Sourbron1,2, M Dujardin2, S Makkat2 and R Luypaert2

Show affiliations


Quantification of haemodynamic parameters with a deconvolution analysis of bolus-tracking data is an ill-posed problem which requires regularization. In a previous study, simulated data without structural errors were used to validate two methods for a pixel-by-pixel analysis: standard-form Tikhonov regularization with either the L-curve criterion (LCC) or generalized cross validation (GCV) for selecting the regularization parameter. However, problems of image artefacts were reported when the methods were applied to patient data. The aim of this study was to investigate the nature of these problems in more detail and evaluate strategies of optimization for routine application in the clinic. In addition we investigated to which extent the calculation time of the algorithm can be minimized. In order to ensure that the conclusions are relevant for a larger range of clinical applications, we relied on patient data for evaluation of the algorithms. Simulated data were used to validate the conclusions in a more quantitative manner. We conclude that the reported problems with image quality can be removed by appropriate optimization of either LCC or GCV. In all examples this could be achieved with LCC without significant perturbation of the values in pixels where the regularization parameter was originally selected accurately. GCV could not be optimized for the renal data, and in the CT data only at the cost of image resolution. Using the implementations given, calculation times were sufficiently short for routine application in the clinic.


PACS

87.19.U- Hemodynamics

87.59.bd Computed radiography

87.57.C- Image quality

Subjects

Medical physics

Biological physics

Dates

Issue 2 (21 January 2007)

Received 27 June 2006, in final form 27 October 2006

Published 29 December 2006



  1. Pixel-by-pixel deconvolution of bolus-tracking data: optimization and implementation

    S Sourbron et al 2007 Phys. Med. Biol. 52 429

  2. X-ray polarimetry in astrophysics with the Gas Pixel Detector

    F Muleri et al 2009 JINST 4 P11002

  3. Recent advances in time and frequency measurement at NTSC

    Shaowu Dong 2003 Metrologia 40 S249

  4. Space charge effects in a kinestatic charge detector

    D J Wagenaar et al 1991 Phys. Med. Biol. 36 61

  5. Simple experiments on the physics of vision: the retina

    Adolf Cortel 2005 Phys. Educ. 40 325

  6. Axial vacuum symmetry of the unified gauge theories with the gravitational mechanism of instability

    V M Nikolaenko 1981 J. Phys. A: Math. Gen. 14 1685

  7. Gravitation: global formulation and quantum effects

    R Aldrovandi et al 2004 Class. Quantum Grav. 21 51

  8. Uncertainty of functionals of calibration curves

    R Willink 2007 Metrologia 44 182

  9. Molecular dynamics simulation of nanoscale machining of copper

    Y Y Ye et al 2003 Nanotechnology 14 390

  10. The new astrometry

    J Kovalevsky 1998 Rep. Prog. Phys. 61 77

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.