Show affiliationsWe performed error analysis of tumor blood flow (TBF) measurement using dynamic contrast-enhanced data and model-independent deconvolution analysis, based on computer simulations. For analysis, we generated a time-dependent concentration of the contrast agent in the volume of interest (VOI) from the arterial input function (AIF) consisting of gamma-variate functions using an adiabatic approximation to the tissue homogeneity model under various plasma flow (Fp), mean capillary transit time (Tc), permeability–surface area product (PS) and signal-to-noise ratio (SNR) values. Deconvolution analyses based on truncated singular value decomposition with a fixed threshold value (TSVD-F), with an adaptive threshold value (TSVD-A) and with the threshold value determined by generalized cross validation (TSVD-G) were used to estimate Fp values from the simulated concentration–time curves in the VOI and AIF. First, we investigated the relationship between the optimal threshold value and SNR in TSVD-F, and then derived the equation describing the relationship between the threshold value and SNR for TSVD-A. Second, we investigated the dependences of the estimated Fp values on Tc, PS, the total duration for data acquisition and the shape of AIF. Although TSVD-F with a threshold value of 0.025, TSVD-A with the threshold value determined by the equation derived in this study and TSVD-G could estimate the Fp values in a similar manner, the standard deviation of the estimates was the smallest and largest for TSVD-A and TSVD-G, respectively. PS did not largely affect the estimates, while Tc did in all methods. Increasing the total duration significantly improved the variations in the estimates in all methods. TSVD-G was most sensitive to the shape of AIF, especially when the total duration was short. In conclusion, this study will be useful for understanding the reliability and limitation of model-independent deconvolution analysis when applied to TBF measurement using an extravascular contrast agent.
87.80.-y Biophysical techniques (research methods)
47.80.-v Instrumentation and measurement methods in fluid dynamics
Issue 10 (21 May 2007)
Received 4 December 2006, in final form 11 March 2007
Published 30 April 2007
Kenya Murase and Shohei Miyazaki 2007 Phys. Med. Biol. 52 2791
Zengyong Li et al 2006 Phys. Med. Biol. 51 2681
K M Langen et al 2003 Phys. Med. Biol. 48 1345
M A Moore and C A Wilson 1980 J. Phys. A: Math. Gen. 13 3501
Lin Jian et al 2007 Chinese Phys. Lett. 24 3280
Isobel C Walker et al 1996 J. Phys. B: At. Mol. Opt. Phys. 29 4749
Benjamin D. G. Chandran and Jason L. Maron 2004 ApJ 602 170
Colin Aspin et al. 2008 The Astronomical Journal 135 423
A Gasmi et al 2009 J. Phys. D: Appl. Phys. 42 225408
T Padmanabhan 2002 Class. Quantum Grav. 19 L167