Quick search Find article
Quick search
Find article

Dual-energy cardiac imaging: an image quality and dose comparison for a flat-panel detector and x-ray image intensifier

Justin L Ducote, Tong Xu and Sabee Molloi

Show affiliations


This study presents a comparison of dual-energy imaging with an x-ray image intensifier and flat-panel detector for cardiac imaging. It also investigates if the wide dynamic range of the flat-panel detector can improve dual-energy image quality while reducing patient dose. Experimental contrast-to-noise (CNR) measurements were carried out in addition to simulation studies. Patient entrance exposure and system tube loading were also recorded. The studied contrast objects were calcium and iodine. System performance was quantified with a figure-of-merit (FOM) defined as the image CNR2 over patient entrance exposure. The range of thickness studied was from 10 to 30 cm of Lucite (PMMA). Detector dose was initially set to 140 nGy (16 µR)/frame. The high-energy 120 kVp beam was filtered by an additional 0.8 mm silver filter. Keeping the same filament current, the kVp for the low-energy beam was adjusted as a function of thickness until 140 nGy was achieved. System performance was found to be similar for both systems, with the x-ray image intensifier performing better at lower thicknesses and the flat-panel detector performing better at higher thicknesses. This requirement of fixed detector entrance exposure was then relaxed and the kVp for the low-energy beam was allowed to vary while the mAs of the x-ray tube remained fixed to study changes in dual-energy image quality, patient dose and FOM with the flat-panel detector. It was found that as the kVp for the low-energy beam was reduced, system performance would rise until reaching a maximum while simultaneously lowering patient exposure. Suggested recommendations for optimal dual-energy imaging implementation are also provided.


PACS

87.19.Hh Cardiac dynamics

87.59.B- Radiography

42.79.Ls Scanners, image intensifiers, and image converters

87.57.C- Image quality

Subjects

Optics, quantum optics and lasers

Medical physics

Biological physics

Dates

Issue 1 (7 January 2007)

Received 24 May 2006, in final form 2 November 2006

Published 14 December 2006



  1. Dual-energy cardiac imaging: an image quality and dose comparison for a flat-panel detector and x-ray image intensifier

    Justin L Ducote et al 2007 Phys. Med. Biol. 52 183

  2. Supersymmetric Quantum Cosmology

    M Ortiz 1998 Class. Quantum Grav. 15

  3. Diquark condensation at strong coupling

    Vicente Azcoiti et al JHEP09(2003)014

  4. Thermodynamic constraints on a time-dependent Lambda model (cosmology)

    J M Salim and I Waga 1993 Class. Quantum Grav. 10 1767

  5. Commissioning, characterization and operation of the dual-recycled GEO 600

    J R Smith et al 2004 Class. Quantum Grav. 21 S1737

  6. Mechanical loss associated with silicate bonding of fused silica

    Joshua R Smith et al 2003 Class. Quantum Grav. 20 5039

  7. Calibration of the dual-recycled GEO 600 detector for the S3 science run

    M Hewitson et al 2004 Class. Quantum Grav. 21 S1711

  8. Upper limits on the strength of periodic gravitational waves from PSR J1939+2134

    B Allen et al 2004 Class. Quantum Grav. 21 S671

  9. On splice site prediction using weight array models: a comparison of smoothing techniques

    Leila Taher et al 2007 J. Phys.: Conf. Ser. 90 012004

  10. Holographic RG Flow on the Defect and g-Theorem

    Satoshi Yamaguchi JHEP10(2002)002

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.