Jan Laufer et al 2007 Phys. Med. Biol. 52 141 doi:10.1088/0031-9155/52/1/010
Jan Laufer, Dave Delpy, Clare Elwell and Paul Beard
Show affiliationsA new approach based on pulsed photoacoustic spectroscopy for non-invasively quantifying tissue chromophore concentrations with high spatial resolution has been developed. The technique is applicable to the quantification of tissue chromophores such as oxyhaemoglobin (HbO2) and deoxyhaemoglobin (HHb) for the measurement of physiological parameters such as blood oxygen saturation (SO2) and total haemoglobin concentration. It can also be used to quantify the local accumulation of targeted contrast agents used in photoacoustic molecular imaging. The technique employs a model-based inversion scheme to recover the chromophore concentrations from photoacoustic measurements. This comprises a numerical forward model of the detected time-dependent photoacoustic signal that incorporates a multiwavelength diffusion-based finite element light propagation model to describe the light transport and a time-domain acoustic model to describe the generation, propagation and detection of the photoacoustic wave. The forward model is then inverted by iteratively fitting it to measurements of photoacoustic signals acquired at different wavelengths to recover the chromophore concentrations. To validate this approach, photoacoustic signals were generated in a tissue phantom using nanosecond laser pulses between 740 nm and 1040 nm. The tissue phantom comprised a suspension of intralipid, blood and a near-infrared dye in which three tubes were immersed. Blood at physiological haemoglobin concentrations and oxygen saturation levels ranging from 2% to 100% was circulated through the tubes. The signal amplitude from different temporal sections of the detected photoacoustic waveforms was plotted as a function of wavelength and the forward model fitted to these data to recover the concentrations of HbO2 and HHb, total haemoglobin concentration and SO2. The performance was found to compare favourably to that of a laboratory CO-oximeter with measurement resolutions of ±3.8 g l−1 (±58 µM) and ±4.4 g l−1 (±68 µM) for the HbO2 and HHb concentrations respectively and ±4% for SO2 with an accuracy in the latter in the range −6%–+7%.
87.64.-t Spectroscopic and microscopic techniques in biophysics and medical physics
Instrumentation and measurement
Issue 1 (7 January 2007)
Received 8 August 2006, in final form 27 October 2006
Published 14 December 2006
Jan Laufer et al 2007 Phys. Med. Biol. 52 141
Vijay Balasubramanian et al JHEP03(2005)007
S Saxena et al 1986 J. Phys. B: At. Mol. Phys. 19 301
Matt Visser and David L Wiltshire 2004 Class. Quantum Grav. 21 1135
Ulvi Yurtsever 1994 Class. Quantum Grav. 11 999
M Kopycinska-Müller et al 2005 Nanotechnology 16 703
Christiana Athanasiou et al JHEP08(2006)055
J Hu et al 1995 Metrologia 31 389
Stéphane Fay 2000 Class. Quantum Grav. 17 1667
Jin Cheng and Masahiro Yamamoto 1998 Inverse Problems 14 869