3D thoracoscopic ultrasound volume measurement validation in an ex vivo and in vivo porcine model of lung tumours

V D M Hornblower1,2,3, E Yu1,4, A Fenster1,2,3,5, J J Battista1,3,4,6 and R A Malthaner1,7

Show affiliations


The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial 'tumours' were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the 'tumours' were implanted into the lung tissue in both a porcine lung sample ex vivo and a surgical porcine model in vivo. 3D US images were created by mechanically rotating the thoracoscopic ultrasound probe about its long axis while the transducer was maintained in close contact with the tissue. Volume measurements were made by one observer using the ultrasound images and a manual-radial segmentation technique and these were compared with the known volumes of the agar. In vitro measurements had average accuracy and precision of 4.76% and 1.77%, respectively; in vivo measurements had average accuracy and precision of 8.18% and 1.75%, respectively. The 3D thoracoscopic ultrasound can be used to accurately and reproducibly measure 'tumour' volumes both in vivo and ex vivo.


PACS

87.63.D- Ultrasonography

87.19.X- Diseases

43.80.Qf Medical diagnosis with acoustics (in PACS, see also 87.63.D−)

Subjects

Biological physics

Medical physics

Dates

Issue 1 (7 January 2007)

Received 31 August 2006, in final form 17 October 2006

Published 6 December 2006



Users also read

What's this?
This innovative new feature generates a list of articles 'also read' by other users based on them reading the original article. Article abstracts citations and references are all considered and weighted accordingly. We hope that this will help you find relevant papers for your research.

  1. History of tomotherapy
  2. Development and preliminary evaluation of a prototype audiovisual biofeedback device incorporating a patient-specific guiding waveform
  3. Simulation of the artefact of an iodine seed placed at the needle tip in MRI-guided prostate brachytherapy
More

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.