Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodes

Yongfeng Yang1, Purushottam A Dokhale2, Robert W Silverman3, Kanai S Shah2, Mickel A McClish2, Richard Farrell2, Gerald Entine2 and Simon R Cherry1

Show affiliations


We explore dual-ended read out of LSO arrays with two position sensitive avalanche photodiodes (PSAPDs) as a high resolution, high efficiency depth-encoding detector for PET applications. Flood histograms, energy resolution and depth of interaction (DOI) resolution were measured for unpolished LSO arrays with individual crystal sizes of 1.0, 1.3 and 1.5 mm, and for a polished LSO array with 1.3 mm pixels. The thickness of the crystal arrays was 20 mm. Good flood histograms were obtained for all four arrays, and crystals in all four arrays can be clearly resolved. Although the amplitude of each PSAPD signal decreases as the interaction depth moves further from the PSAPD, the sum of the two PSAPD signals is essentially constant with irradiation depth for all four arrays. The energy resolutions were similar for all four arrays, ranging from 14.7% to 15.4%. A DOI resolution of 3–4 mm (including the width of the irradiation band which is ~2 mm) was obtained for all the unpolished arrays. The best DOI resolution was achieved with the unpolished 1 mm array (average 3.5 mm). The DOI resolution for the 1.3 mm and 1.5 mm unpolished arrays was 3.7 and 4.0 mm respectively. For the polished array, the DOI resolution was only 16.5 mm. Summing the DOI profiles across all crystals for the 1 mm array only degraded the DOI resolution from 3.5 mm to 3.9 mm, indicating that it may not be necessary to calibrate the DOI response separately for each crystal within an array. The DOI response of individual crystals in the array confirms this finding. These results provide a detailed characterization of the DOI response of these PSAPD-based PET detectors which will be important in the design and calibration of a PET scanner making use of this detector approach.


PACS

87.57.uk Positron emission tomography (PET)

06.20.fb Standards and calibration

85.60.Dw Photodiodes; phototransistors; photoresistors

87.63.-d Non-ionizing radiation equipment and techniques

87.57.C- Image quality

Subjects

Electronics and devices

Instrumentation and measurement

Optics, quantum optics and lasers

Medical physics

Dates

Issue 9 (7 May 2006)

Received 20 January 2006, in final form 24 February 2006

Published 11 April 2006



Users also read

What's this?
This innovative new feature generates a list of articles 'also read' by other users based on them reading the original article. Article abstracts citations and references are all considered and weighted accordingly. We hope that this will help you find relevant papers for your research.

  1. A study of the timing properties of position-sensitive avalanche photodiodes
  2. Tapered LSO arrays for small animal PET
  3. Depth of interaction calibration for PET detectors with dual-ended readout by PSAPDs
More

Related review articles

What's this?
View review articles related to this research to gain an insight into the key trends in this subject area. Related review articles are selected based on PACS/MSC codes, and are no more than three years old.

  1. SPECT detectors: the Anger Camera and beyond
  2. Review and current status of SPECT scatter correction
  3. Dynamic single photon emission computed tomography—basic principles and cardiac applications
More

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.