Yong Du et al 2006 Phys. Med. Biol. 51 1269 doi:10.1088/0031-9155/51/5/016
Yong Du, Benjamin M W Tsui and Eric C Frey
Show affiliationsPreviously we have developed a model-based method that can accurately estimate downscatter contamination from high-energy photons in 123I imaging. In this work we combined the model-based method with iterative reconstruction-based compensations for other image-degrading factors such as attenuation, scatter, the collimator-detector response function (CDRF) and partial volume effects to form a comprehensive method for performing quantitative 123I SPECT image reconstruction. In the model-based downscatter estimation method, photon scatter inside the object was modelled using the effective source scatter estimation (ESSE) technique, including contributions from all the photon emissions. The CDRFs, including the penetration and scatter components due to the high-energy 123I photons, were estimated using Monte Carlo (MC) simulations of point sources in air at various distances from the face of the collimator. The downscatter contamination was then compensated for during the iterative reconstruction by adding the estimated results to the projection steps. The model-based downscatter compensation (MBDC) was evaluated using MC simulated and experimentally acquired projection data. From the MC simulation, we found about 39% of the total counts in the energy window of 123I were attributed to the downscatter contamination, which reduced image contrast and caused a 1.5% to 10% overestimation of activities in various brain structures. Model-based estimates of the downscatter contamination were in good agreement with the simulated data. Compensation using MBDC removed the contamination and improved the image contrast and quantitative accuracy to that of the images obtained from 159 keV photons. The errors in absolute quantitation were reduced to within ±3.5%. The striatal specific binding potential calculated based on the activity ratio to the background was also improved after MBDC. The errors were reduced from −4.5% to −10.93% without compensation to −0.55% to 4.87% after compensation. The model-based method provided accurate downscatter estimation and, when combined with iterative reconstruction-based compensations, accurate quantitation was obtained with minimal loss of precision.
87.57.uh Single photon emission computed tomography (SPECT)
Issue 5 (7 March 2006)
Received 8 July 2005, in final form 23 December 2005
Published 15 February 2006
Yong Du et al 2006 Phys. Med. Biol. 51 1269
Melanie David et al 2006 J. Phys.: Condens. Matter 18 1137
Andrew Wallard 2008 Metrologia 45 119
E Orlandini et al 2004 J. Phys. A: Math. Gen. 37 1535
G B Brière 1964 Br. J. Appl. Phys. 15 413
Peter Pesic 2005 Eur. J. Phys. 26 183
Michael C LoPresto 2003 Phys. Educ. 38 309
Yongqing Fu et al 2001 J. Phys. D: Appl. Phys. 34 1430
R S Davis 1992 Metrologia 29 67
Y T C Ko et al 2004 J. Phys.: Condens. Matter 16 499