Quick search Find article
Quick search
Find article

Comparison and evaluation of mouse cardiac MRI acquired with open birdcage, single loop surface and volume birdcage coils

Xiaobing Fan, Erica J Markiewicz, Marta Zamora, Gregory S Karczmar and Brian B Roman

Show affiliations


NOTE

Although the quality and speed of MR images have vastly improved with the development of novel RF coil technologies, the engineering expertise required to implement them is often not available in many animal in vivo MR laboratories. We present here an open birdcage coil design which is easily constructed with basic RF coil expertise and produces high quality images. The quality and advantages of mouse cardiac MR images acquired with open birdcage coils were evaluated and compared to images acquired with a bent single loop surface, and standard birdcage coils acquired at 4.7 Tesla. Two low pass open birdcage coils, two single loop surface coils, and a low pass volume birdcage coil were constructed and their B1 distributions were evaluated and compared. The calculated average signal-to-noise ratio for the left ventricular wall was 10, 23 and 32 for the volume birdcage coil, single loop surface coil and open birdcage coil, respectively. The results demonstrate that the open birdcage coil provides greater sensitivity than the volume coil and a higher signal/contrast-to-noise ratio and B1 homogeneity than the single loop surface coil. The open birdcage coil offers easy access and better quality mouse cardiac imaging than both the single loop surface coil and volume birdcage coil and does not require extensive RF engineering expertise to construct.


PACS

87.61.Tg Clinical applications

87.57.C- Image quality

87.19.Hh Cardiac dynamics

Subjects

Biological physics

Medical physics

Dates

Issue 24 (21 December 2006)

Received 19 July 2006, in final form 23 October 2006

Published 24 November 2006



Related review articles

What's this?
View review articles related to this research to gain an insight into the key trends in this subject area. Related review articles are selected based on PACS/MSC codes, and are no more than three years old.

  1. Interaction of MRI field gradients with the human body
  2. Physics of magnetic resonance imaging: from spin to pixel

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.