Is correction necessary when clinically determining quantitative cerebral perfusion parameters from multi-slice dynamic susceptibility contrast MR studies?*

M Salluzzi1, R Frayne1,2,3,4 and M R Smith1,2

Show affiliations


Several groups have modified the standard singular value decomposition (SVD) algorithm to produce delay-insensitive cerebral blood flow (CBF) estimates from dynamic susceptibility contrast (DSC) perfusion studies. However, new dependences of CBF estimates on bolus arrival times and slice position in multi-slice studies have been recently recognized. These conflicting findings can be reconciled by accounting for several experimental and algorithmic factors. Using simulation and clinical studies, the non-simultaneous measurement of arterial and tissue concentration curves (relative slice position) in a multi-slice study is shown to affect time-related perfusion parameters, e.g. arterial-tissue-delay measurements. However, the current clinical impact of relative slice position on amplitude-related perfusion parameters, e.g. CBF, can be expected to be small unless any of the following conditions are present individually or in combination: (a) high concentration curve signal-to-noise ratios, (b) small tissue mean transit times, (c) narrow arterial input functions or (d) low temporal resolution of the DSC image sequence. Recent improvements in magnetic resonance (MR) technology can easily be expected to lead to scenarios where these effects become increasingly important sources of inaccuracy for all perfusion parameter estimates. We show that using Fourier interpolated (high temporal resolution) residue functions reduces the systematic error of the perfusion parameters obtained from multi-slice studies.


Footnote
*  Preliminary results associated with this paper were presented at ISMRM 12th Scientific Meeting and Exhibition, Kyoto, Japan, 2004.
PACS

87.61.Tg Clinical applications

47.63.Jd Microcirculation and flow through tissues

87.19.L- Neuroscience

87.19.rh Fluid transport and rheology

02.60.Ed Interpolation; curve fitting

02.30.Nw Fourier analysis

Subjects

Fluid dynamics

Mathematical physics

Computational physics

Biological physics

Medical physics

Dates

Issue 2 (21 January 2006)

Received 3 August 2005, in final form 1 November 2005

Published 4 January 2006



Related review articles

What's this?
View review articles related to this research to gain an insight into the key trends in this subject area. Related review articles are selected based on PACS/MSC codes, and are no more than three years old.

  1. Interaction of MRI field gradients with the human body
  2. Physics of magnetic resonance imaging: from spin to pixel

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.