Quick search Find article
Quick search
Find article

Comparison of conventional, model-based quantitative planar, and quantitative SPECT image processing methods for organ activity estimation using In-111 agents

Bin He and Eric C Frey

Show affiliations


Accurate quantification of organ radionuclide uptake is important for patient-specific dosimetry. The quantitative accuracy from conventional conjugate view methods is limited by overlap of projections from different organs and background activity, and attenuation and scatter. In this work, we propose and validate a quantitative planar (QPlanar) processing method based on maximum likelihood (ML) estimation of organ activities using 3D organ VOIs and a projector that models the image degrading effects. Both a physical phantom experiment and Monte Carlo simulation (MCS) studies were used to evaluate the new method. In these studies, the accuracies and precisions of organ activity estimates for the QPlanar method were compared with those from conventional planar (CPlanar) processing methods with various corrections for scatter, attenuation and organ overlap, and a quantitative SPECT (QSPECT) processing method. Experimental planar and SPECT projections and registered CT data from an RSD Torso phantom were obtained using a GE Millenium VH/Hawkeye system. The MCS data were obtained from the 3D NCAT phantom with organ activity distributions that modelled the uptake of 111In ibritumomab tiuxetan. The simulations were performed using parameters appropriate for the same system used in the RSD torso phantom experiment. The organ activity estimates obtained from the CPlanar, QPlanar and QSPECT methods from both experiments were compared. From the results of the MCS experiment, even with ideal organ overlap correction and background subtraction, CPlanar methods provided limited quantitative accuracy. The QPlanar method with accurate modelling of the physical factors increased the quantitative accuracy at the cost of requiring estimates of the organ VOIs in 3D. The accuracy of QPlanar approached that of QSPECT, but required much less acquisition and computation time. Similar results were obtained from the physical phantom experiment. We conclude that the QPlanar method, based on 3D organ VOIs and accurate models of the projection process, provided a substantial increase in accuracy of organ activity estimates from planar images compared to CPlanar processing and had accuracy approaching that of QSPECT.


PACS

87.57.uh Single photon emission computed tomography (SPECT)

87.57.uq Dosimetry

87.57.U- Nuclear medicine imaging

87.57.N- Image analysis

87.56.Da Ancillary equipment

Subjects

Medical physics

Dates

Issue 16 (21 August 2006)

Received 4 May 2006, in final form 16 June 2006

Published 2 August 2006



  1. Comparison of conventional, model-based quantitative planar, and quantitative SPECT image processing methods for organ activity estimation using In-111 agents

    Bin He and Eric C Frey 2006 Phys. Med. Biol. 51 3967

  2. Negativity of the Wigner function as an indicator of non-classicality

    Anatole Kenfack and Karol Życzkowski 2004 J. Opt. B: Quantum Semiclass. Opt. 6 396

  3. Citations Prize 2009

    Steve Webb and Simon Harris 2009 Phys. Med. Biol. 54

  4. Integration of polymer and metal microstructures using liquid-phase photopolymerization

    Abhishek K Agarwal et al 2006 J. Micromech. Microeng. 16 332

  5. Fabrication of thick silicon dioxide sacrificial and isolation blocks in a silicon substrate

    Hongrui Jiang et al 2002 J. Micromech. Microeng. 12 87

  6. Galaxy Structural Parameters: Star Formation Rate and Evolution with Redshift

    M. Takamiya 1999 ApJS 122 109

  7. Free expansion of two-dimensional condensates with a vortex

    O Hosten et al 2003 J. Phys. B: At. Mol. Opt. Phys. 36 2455

  8. Boson–fermion mixtures inside an elongated cigar-shaped trap

    Z Akdeniz et al 2005 J. Phys. B: At. Mol. Opt. Phys. 38 2933

  9. Mapping metals in Parkinson's and normal brain using rapid-scanning x-ray fluorescence

    Bogdan F Gh Popescu et al 2009 Phys. Med. Biol. 54 651

  10. Subtleties in energy calculations in the image method

    M M Taddei et al 2009 Eur. J. Phys. 30 965

Related review articles

What's this?
View review articles related to this research to gain an insight into the key trends in this subject area. Related review articles are selected based on PACS/MSC codes, and are no more than three years old.

  1. SPECT detectors: the Anger Camera and beyond
  2. Review and current status of SPECT scatter correction
  3. Dynamic single photon emission computed tomography—basic principles and cardiac applications
More

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.