K R Gorny et al 2006 Phys. Med. Biol. 51 3155 doi:10.1088/0031-9155/51/12/011
K R Gorny, N J Hangiandreou, G K Hesley, B S Gostout, K P McGee and J P Felmlee
Show affiliationsMagnetic resonance (MR) guided focused ultrasound (MRgFUS) is a hybrid technique which offers efficient and safe focused ultrasound (FUS) treatments of uterine fibroids under MR guidance and monitoring. As a therapy device, MRgFUS requires systematic testing over a wide range of operational parameters prior to use in the clinical environment. We present technical acceptance tests and data for the first clinical MRgFUS system, ExAblate® 2000 (InSightec Inc., Haifa, Israel), that has been FDA approved for treating uterine fibroids. These tests characterize MRgFUS by employing MR temperature measurements in tissue mimicking phantoms. The coronal scan plane is empirically demonstrated to be most reliable for measuring temperature elevations resulting from high intensity ultrasound (US) pulses ('sonications') and shows high sensitivity to changes in sonication parameters. Temperatures measured in the coronal plane were used as a measure of US energy deposited within the focal spot for a range of sonication parameters used in clinical treatments: spot type, spot length, output power, sonication duration, US frequency, and depth of sonication. In addition, MR images acquired during sonications were used to measure effective diameters and lengths of available sonication spot types and lengths. At a constant 60 W output power, the effective spot type diameters were measured to vary between 4.7 ± 0.3 mm and 6.6 ± 0.4 mm; treatment temperatures were found to decrease with increasing spot diameter. Prescribing different spot lengths was found to have no effect on the measured length or on measured temperatures. Tests of MRgFUS positioning accuracy determined errors in the direction parallel to the propagation of the US beam to be significantly greater than those in the perpendicular direction; most sonication spots were erroneously positioned towards the FUS transducer. The tests reported here have been demonstrated to be sufficiently sensitive to detect water leakage inside the FUS transducer. The data presented could be used for comparison by those conducting acceptance tests on other clinical MRgFUS systems.
87.50.yt Therapeutic applications
43.80.Vj Acoustical medical instrumentation and measurement techniques
Issue 12 (21 June 2006)
Received 4 February 2006, in final form 6 February 2006
Published 6 June 2006
K R Gorny et al 2006 Phys. Med. Biol. 51 3155
Jeffrey W. Brosius et al. 2002 ApJ 574 453
Christopher J. Conselice et al. 2003 ApJ 591 167
Nobuo Misawa and Shoji Takeuchi 2009 J. Micromech. Microeng. 19 115032
Wei-Qiang Han et al 2009 Nanotechnology 20 495605
Katsuaki Asano and Susumu Inoue 2007 ApJ 671 645
Jeffrey S. Oishi and Mordecai-Mark Mac Low 2006 ApJ 638 281
Ren-Bao Liu and Bang-fen Zhu 2000 J. Phys.: Condens. Matter 12 L741
W S Brams Dwandaru and Matthias Schmidt 2007 J. Phys. A: Math. Theor. 40 13209
G Heinzel et al 2003 Class. Quantum Grav. 20 S153