Mikko S Laasanen et al 2005 Phys. Med. Biol. 50 N49 doi:10.1088/0031-9155/50/7/N01
Mikko S Laasanen1, Jari O Heikkinen1, Simo Saarakkala1 and Hannu Paajanen2
Show affiliationsGamma camera imaging with Tc-99m marking is a widely used method to locate sentinel lymph nodes (SNs) in breast cancer patients. Prior to SN biopsy, the anterior and lateral location of the SN is marked on the patient's skin using an ink pen. The pen marks guide the surgeon during an operation. However, in many cases the marking is difficult due to limited space under the detectors of a gamma camera. The aim of this study was to improve the pen marking method. Eleven female patients were imaged 3–4 h after injection of Tc-99m labelled Nanocol©. Injection was performed to parenchyma surrounding the breast tumour. To facilitate pen marking, two polycarbonate (PC) plates with 40 × 32 holes (spacing = 10 mm) were engineered for anterior and lateral side imaging and then installed on the bed of a dual-head gamma camera. Two drops of Tc-99m were placed into the top corners of both the PC plates, in order to trace the corresponding x–y coordinates first from the acquired images and then from the plates. After imaging, the x–y coordinates of the SN(s) were determined from the anterior and lateral side images. Subsequently, the location of each SN was marked with an ink pen on the skin through the small holes in the PC plates. According to the surgeon's evaluation, the distance between the marks and the true location of the SNs was 4.5 ± 6.9 mm. Measurements with a custom made phantom revealed that the accuracy of the novel method was significantly (P = 0.06) higher as compared with the traditional method (2.7 ± 3.0 mm versus 9.2 ± 3.0 mm). In addition, we were not able to mark the weakest activity (0.02 MBq) with the traditional method. Taken together, the marking process was considerably easier with the novel method, it had better accuracy and sensitivity than the traditional method and the device is simple enough to be adapted for most gamma cameras.
87.63.-d Non-ionizing radiation equipment and techniques
07.85.Fv X- and gamma-ray sources, mirrors, gratings, and detectors
Issue 7 (7 April 2005)
Received 10 November 2004, in final form 7 January 2005
Published 16 March 2005
Mikko S Laasanen et al 2005 Phys. Med. Biol. 50 N49
A K Kazansky and N M Kabachnik 2009 J. Phys. B: At. Mol. Opt. Phys. 42 121002
David V Sheludko et al 2007 J. Phys.: Conf. Ser. 80 012040
Ataru Kobayashi et al 2002 J. Phys. B: At. Mol. Opt. Phys. 35 2087
K A Bronnikov and S A Kononogov 2006 Metrologia 43 R1
A R Curtis and N P R Sherry 1977 J. Phys. D: Appl. Phys. 10 481
X L Chen and K M Liew 2004 Smart Mater. Struct. 13 1430
Y De Deene et al 2003 Phys. Med. Biol. 48 L15
Wang Ya-Nan et al 2008 Chinese Phys. B 17 1448
Sang-Yup Lee et al 2005 Nanotechnology 16 S435