A Monte Carlo and physical phantom evaluation of quantitative In-111 SPECT

Bin He, Yong Du, Xiyun Song, W Paul Segars and Eric C Frey

Show affiliations


Accurate estimation of the 3D in vivo activity distribution is important for dose estimation in targeted radionuclide therapy (TRT). Although SPECT can potentially provide such estimates, SPECT without compensation for image degrading factors is not quantitatively accurate. In this work, we evaluated quantitative SPECT (QSPECT) reconstruction methods that include compensation for various physical effects. Experimental projection data were obtained using a GE VH/Hawkeye system and an RSD torso phantom. Known activities of In-111 chloride were placed in the lungs, liver, heart, background and two spherical compartments with inner diameters of 22 mm and 34 mm. The 3D NCAT phantom with organ activities based on clinically derived In-111 ibritumomab tiuxetan data was used for the Monte Carlo (MC) simulation studies. Low-noise projection data were simulated using previously validated MC simulation methods. Fifty sets of noisy projections with realistic count levels were generated. Reconstructions were performed using the OS-EM algorithm with various combinations of attenuation (A), scatter (S), geometric response (G), collimator–detector response (D) and partial volume compensation (PVC). The QSPECT images from the various combinations of compensations were evaluated in terms of the accuracy and precision of the estimates of the total activity in each organ. For experimental data, the errors in organ activities for ADS and PVC compensation were less than 6.5% except the smaller sphere (−11.9%). For the noisy simulated data, the errors in organ activity for ADS compensation were less than 5.5% except the lungs (20.9%) and blood vessels (15.2%). Errors for other combinations of compensations were significantly (A, AS) or somewhat (AGS) larger. With added PVC, the error in the organ activities improved slightly except for the lungs (11.5%) and blood vessels (3.6%) where the improvement was more substantial. The standard deviation/mean ratios were all less than 1.5%. We conclude that QSPECT methods with appropriate compensations provided accurate In-111 organ activity estimates. For the collimator used, AGS was almost as good as ADS and may be preferable due to the reduced reconstruction time. PVC was important for small structures such as tumours or for organs in close proximity to regions with high activity. The improved quantitative accuracy from QSPECT methods has the potential for improving organ dose estimations in TRT.


PACS

87.57.uh Single photon emission computed tomography (SPECT)

87.55.K- Monte Carlo methods

87.56.J- Collimation

87.55.-x Treatment strategy

87.56.Da Ancillary equipment

87.19.X- Diseases

Subjects

Biological physics

Medical physics

Dates

Issue 17 (7 September 2005)

Received 21 January 2005, in final form 9 June 2005

Published 23 August 2005



  1. A Monte Carlo and physical phantom evaluation of quantitative In-111 SPECT

    Bin He et al 2005 Phys. Med. Biol. 50 4169

  2. Nonlinear physics of the ionosphere and LOIS/LOFAR

    Bo Thidé 2007 Plasma Phys. Control. Fusion 49 B103

  3. On the use of Tedlar® bags for breath-gas sampling and analysis

    Jonathan Beauchamp et al 2008 J. Breath Res. 2 046001

  4. Wavelet compression in medical terahertz pulsed imaging

    J W Handley et al 2002 Phys. Med. Biol. 47 3885

  5. Comparison of conventional, model-based quantitative planar, and quantitative SPECT image processing methods for organ activity estimation using In-111 agents

    Bin He and Eric C Frey 2006 Phys. Med. Biol. 51 3967

  6. Negativity of the Wigner function as an indicator of non-classicality

    Anatole Kenfack and Karol Życzkowski 2004 J. Opt. B: Quantum Semiclass. Opt. 6 396

  7. Citations Prize 2009

    Steve Webb and Simon Harris 2009 Phys. Med. Biol. 54

  8. Integration of polymer and metal microstructures using liquid-phase photopolymerization

    Abhishek K Agarwal et al 2006 J. Micromech. Microeng. 16 332

  9. Fabrication of thick silicon dioxide sacrificial and isolation blocks in a silicon substrate

    Hongrui Jiang et al 2002 J. Micromech. Microeng. 12 87

  10. Galaxy Structural Parameters: Star Formation Rate and Evolution with Redshift

    M. Takamiya 1999 ApJS 122 109

Related review articles

What's this?
View review articles related to this research to gain an insight into the key trends in this subject area. Related review articles are selected based on PACS/MSC codes, and are no more than three years old.

  1. SPECT detectors: the Anger Camera and beyond
  2. Review and current status of SPECT scatter correction
  3. Dynamic single photon emission computed tomography—basic principles and cardiac applications
More

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.