Quick search Find article
Quick search
Find article

Characterization of a 2D ion chamber array for the verification of radiotherapy treatments

E Spezi, A L Angelini, F Romani and A Ferri

Show affiliations


In this study we investigated the characteristics of a commercial ion chamber array and its performance in the verification of radiotherapy plans. The device was the 2D Array Seven29™ model (PTW, Freiburg, Germany). This is a two-dimensional detector array with 729 ionization chambers uniformly arranged in a 27 × 27 matrix with an active area of 27 × 27 cm2. The detector short-, medium- and long-term reproducibility have been tested through an extensive set of repeated measurements. Short-term reproducibility was well within 0.2%. Medium- and long-term reproducibility were within 1%, including set-up reproducibility errors and linac output fluctuations. Dose linearity was also assessed. The system response to dose was verified to be linear within the range 2–500 MU. Output factors matched very well pinpoint chamber measurements performed in the same experimental conditions with a maximum local percentage difference of 0.4%. Furthermore, the 2D Array sensitivity to millimetric collimator positional changes and to perturbation effect of irradiated area was tested. The comparison with ion chamber data carried out in water was very satisfying. Finally, measurements of wedge-modulated fields and IMRT beam sequence matched very well ion chamber dose profiles acquired in a water tank. The extensive tests performed in this investigation show that the 2D Array Seven29 is a reliable and accurate dosimeter and that it could be a useful tool for the quality assurance and the verification of radiotherapy plans.


PACS

87.55.T- Record and verify systems and applications

87.53.Bn Dosimetry/exposure assessment

87.56.ng Wedges and compensators

87.55.-x Treatment strategy

87.56.J- Collimation

87.56.Da Ancillary equipment

Subjects

Medical physics

Dates

Issue 14 (21 July 2005)

Received 18 April 2005, in final form 1 June 2005

Published 6 July 2005



  1. Characterization of a 2D ion chamber array for the verification of radiotherapy treatments

    E Spezi et al 2005 Phys. Med. Biol. 50 3361

  2. Gamma-ray scattering for fat fraction measurement

    J Shakeshaft et al 1997 Phys. Med. Biol. 42 1403

  3. Langton's flies

    P Dorbec and A Gajardo 2008 J. Phys. A: Math. Theor. 41 405101

  4. Electrospray deposition of carbon nanotubes in vacuum

    James N O'Shea et al 2007 Nanotechnology 18 035707

  5. Closed-form weak-field expansion of two-loop Euler-Heisenberg Lagrangians

    Gerald V. Dunne et al JHEP11(2006)013

  6. Uncertainties in the composition of Earth, its core and silicate sphere

    William F McDonough and Ricardo Arevalo Jr 2008 J. Phys.: Conf. Ser. 136 022006

  7. Constrained dynamics of universally coupled massive spin 2-spin 0 gravities

    J Brian Pitts 2006 J. Phys.: Conf. Ser. 33 279

  8. Electromagnetic modelling of current flow in the heart from TASER devices and the risk of cardiac dysrhythmias

    S J Holden et al 2007 Phys. Med. Biol. 52 7193

  9. Negative differential magnetoresistance and commensurability oscillations of two-dimensional electrons in a disordered array of antidots

    G M Gusev et al 1994 J. Phys.: Condens. Matter 6 73

  10. The radiometer revisited

    M Goldman 1978 Phys. Educ. 13 427

Related review articles

What's this?
View review articles related to this research to gain an insight into the key trends in this subject area. Related review articles are selected based on PACS/MSC codes, and are no more than three years old.

  1. The history of IRPA—up to the millennium
  2. Malignant pleural mesothelioma risk among nuclear workers: a review

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.