Comparison between TG-51 and TRS-398: electron contamination effect on photon beam-quality specification

Antonio Lopez Medina1, Antonio Teijeiro1, Francisco Salvador1, Daniela Medal1, Julio Vazquez1, Manuel Salgado1 and María C Carrion2

Show affiliations


Two dosimetry protocols based on absorbed dose to water have recently been implemented: TG-51 and TRS-398. These protocols use different beam-quality indices: %dd(10)x and TPR20,10. The effect of electron contamination in measurements of %dd(10)x has been proposed as a disadvantage of the TG-51. For actual measurements of %dd(10)x in five clinical beams (Primus 6–18 MV, SL-75/5 6 MV, SL-18 6–15 MV) a purging magnet was employed to remove the electron contamination. Also, %dd(10)x was measured in the different ways described in TG-51 for high-energy beams: with a lead foil at 50 cm from the phantom surface, at 30 cm, and for open beam. Moreover, TPR20,10 was determined. Also, periodic quality-control measurements were used for comparing both quality indices and variation over time, but D20,10 was used instead of TPR20,10 and measurements in open beam for the %dd(10)x determination. Considering both protocols, Sw,air and kQ were calculated in order to compare the results with the experimental data. Significant differences (0.3% for kQ) were only found for the two high-energy beams, but when the electron contamination is underestimated by TG-51, the difference in kQ is lower. Differences in the other cases and variations over time were less than 0.1%.


PACS

87.53.Bn Dosimetry/exposure assessment

87.56.Da Ancillary equipment

87.55.Qr Quality assurance in radiotherapy

Subjects

Medical physics

Dates

Issue 1 (7 January 2004)

Received 29 May 2003, in final form 11 November 2003

Published 15 December 2003



  1. Comparison between TG-51 and TRS-398: electron contamination effect on photon beam-quality specification

    Antonio Lopez Medina et al 2004 Phys. Med. Biol. 49 17

  2. Significance of the Formal Quantum Number in the Highly Excited Vibration of the DCN molecule

    Zheng Dun-Sheng and Wu Guo-Zhen 2002 Chinese Phys. Lett. 19 466

  3. Can quantum information be cloned in Kerr black holes?

    Xian-Hui Ge and You-Gen Shen 2004 Class. Quantum Grav. 21 1941

  4. Collider signals of gravitational fixed points

    JoAnne L. Hewett and Thomas G. Rizzo JHEP12(2007)009

  5. On the reduction of the multidimensional stationary Schrödinger equation to a first-order equation and its relation to the pseudoanalytic function theory

    Vladislav V Kravchenko 2005 J. Phys. A: Math. Gen. 38 851

  6. An introduction to conformal Ricci flow

    Arthur E Fischer 2004 Class. Quantum Grav. 21 S171

  7. Calculation of multipole transitions at the Fe K pre-edge through p-d hybridization in the Ligand Field Multiplet model

    M.-A. Arrio et al 2000 Europhys. Lett. 51 454

  8. Infrared emittance of Cux–Ni1−x alloys

    K Gelin and E Wäckelgård 2004 J. Phys.: Condens. Matter 16 833

  9. Comment on ``The black hole final state''

    Daniel Gottesman and John Preskill JHEP03(2004)026

  10. Development and validation of a processing map for zirconium alloys

    S V S Narayana Murty et al 2002 Modelling Simul. Mater. Sci. Eng. 10 503

Users also read

What's this?
This innovative new feature generates a list of articles 'also read' by other users based on them reading the original article. Article abstracts citations and references are all considered and weighted accordingly. We hope that this will help you find relevant papers for your research.

  1. Comparison of the IAEA TRS-398 and AAPM TG-51 absorbed dose to water protocols in the dosimetry of high-energy photon and electron beams

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.