Quick search Find article
Quick search
Find article

Use of recovery coefficients as a test of system linearity of response in positron emission tomography (PET)

Bernd O Knoop1, Lilli Geworski2, Michael Hofmann1, Dieter L Munz2 and Wolfram H Knapp1

Show affiliations


Quantitative determination of activity concentration has always been regarded as a goal of PET scanner design. Therefore, a linear response with respect to activity concentration is essential. To prove system linearity of response a test is proposed based on the determination of recovery coefficients (RC) for different object geometries. If all degrading effects, especially scatter and attenuation, are corrected to a sufficient degree of accuracy, the system behaves linearly resulting in a theoretical relationship between hot (HSRC) and cold spot recovery coefficients (CSRC). Therefore this relationship, applied to appropriate phantom data containing hot or cold spheres, combined with the constraints on asymptotic behaviour of RC can be used as a test of system linearity of response.

After applying the system's standard corrections RC were determined using both 2D and 3D data acquisition modes. For both 2D and 3D data, HSRC directly measured showed an excellent agreement with the HSRC calculated from the CSRC. The analysis was extended to radionuclides of different positron ranges, to the effect of data smoothing, and to that of iterative reconstruction. The agreement between the RC determined under varying border conditions demonstrates the effectiveness of the corrections used in constituting system linearity. Therefore, the method proposed is used as a test of system linearity of response.


PACS

87.57.uk Positron emission tomography (PET)

87.63.-d Non-ionizing radiation equipment and techniques

87.57.N- Image analysis

Subjects

Medical physics

Dates

Issue 8 (21 April 2002)

Received 27 July 2001, in final form 21 February 2002

Published 5 April 2002



  1. Use of recovery coefficients as a test of system linearity of response in positron emission tomography (PET)

    Bernd O Knoop et al 2002 Phys. Med. Biol. 47 1237

  2. A metal mixture lowers the reaction temperature of copper chloride as shown using in situ quick XAFS

    Takashi Fujimori et al 2009 J. Phys.: Conf. Ser. 190 012183

  3. Estimation of hygrometry uncertainties by propagation of distributions

    Vincent Carpentier et al 2004 Metrologia 41 432

  4. Microstructure fabrication with a CO2 laser system

    Detlef Snakenborg et al 2004 J. Micromech. Microeng. 14 182

  5. Time-resolved photoluminescence spectroscopy of ligand-capped PbS nanocrystals

    Jamie H Warner et al 2005 Nanotechnology 16 175

  6. Evaluation of coaxial bridge systems for accurate determination of the SI Farad from the DC quantum Hall effect

    S A Awan et al 2003 Metrologia 40 264

  7. Negative thermal expansion and local dynamics

    P Fornasini et al 2009 J. Phys.: Conf. Ser. 190 012025

  8. Composed ensembles of random unitary matrices

    Marcin Pozniak et al 1998 J. Phys. A: Math. Gen. 31 1059

  9. L-shell x-ray fluorescence measurements of lead in bone: system development

    Andrew C Todd 2002 Phys. Med. Biol. 47 507

  10. Crazy things that we teach in physics

    Keith S Taber 2008 Phys. Educ. 43 122

Related review articles

What's this?
View review articles related to this research to gain an insight into the key trends in this subject area. Related review articles are selected based on PACS/MSC codes, and are no more than three years old.

  1. SPECT detectors: the Anger Camera and beyond
  2. Review and current status of SPECT scatter correction
  3. Dynamic single photon emission computed tomography—basic principles and cardiac applications
More

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.