Receptor dose in digital fluorography: a comparison between theory and practice

N W Marshall, C J Kotre, K J Robson and A R Lecomber

Show affiliations


A method of identifying the dose per image when quantum mottle no longer dominates the image statistics is presented as a first step towards quantitative optimization in native and subtracted digital fluorography. The method is based on measurements of threshold contrast over a range of receptor doses and the application of a simple model of the threshold contrast detection task to estimate the magnitude of system noise sources. The point at which system and quantum noise sources are equal in magnitude is proposed as the practical upper limit for dose per image. The method is applied to a typical digital fluorography system and the results are placed into the context of the range of dose per image values found from a regional survey of digital fluorography units. While there is broad agreement between the dose per image values in the survey with values predicted from the experimental method, the considerable spread in survey doses suggests there are instances where the use of a high dose per image is unjustified.


PACS

87.59.C- Fluoroscopy

87.57.C- Image quality

Subjects

Medical physics

Dates

Issue 4 (April 2001)

Received 17 August 2000, in final form 4 January 2001



Users also read

What's this?
This innovative new feature generates a list of articles 'also read' by other users based on them reading the original article. Article abstracts citations and references are all considered and weighted accordingly. We hope that this will help you find relevant papers for your research.

  1. Image quality assessment in digital mammography: part I. Technical characterization of the systems
  2. Monte Carlo dose verification for intensity-modulated arc therapy
  3. The practical application of signal detection theory to image quality assessment in x-ray image intensifier-TV fluoroscopy

Related review articles

What's this?
View review articles related to this research to gain an insight into the key trends in this subject area. Related review articles are selected based on PACS/MSC codes, and are no more than three years old.

  1. Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction?

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.