K X-ray fluorescence measurements of bone lead concentration: the analysis of low-level data

R Kim, A Aro, A Rotnitzky, C Amarasiriwardena and H Hu

Show affiliations


K line X-ray fluorescence (KXRF) measurements of bone lead have emerged as a promising new biological marker of internal lead dose in epidemiological studies. Some disagreements exist, however, over the analysis of data at low levels of bone lead concentration. Here, the authors performed 30 serial measurements on each of three phantoms containing spiked amounts of lead. Chemical analysis of these phantoms using an inductively coupled plasma mass spectrometer (ICPMS) indicated that the lead concentrations were 0.30, 5.77, and 11.57 mu g g-1. Analysis of the data was performed using several definitions of a minimum detectable limit (MDL) to recode data below the MDL, and using all of the continuous point estimates of lead concentration in the phantom (including negative estimates). The results demonstrate that the use of MDLs to recode low-level observations reduces the efficiency of the analysis and the ability to distinguish between the phantoms. Retaining all point estimates of KXRF-measured bone lead concentration provides less bias and greater efficiency in comparing the mean or median levels of bone lead of different populations.


PACS

87.64.kd X-ray and EXAFS

82.80.Ms Mass spectrometry (including SIMS, multiphoton ionization and resonance ionization mass spectrometry, MALDI)

Subjects

Medical physics

Biological physics

Chemical physics and physical chemistry

Dates

Issue 9 (September 1995)



  1. K X-ray fluorescence measurements of bone lead concentration: the analysis of low-level data

    R Kim et al 1995 Phys. Med. Biol. 40 1475

  2. Damage spreading and dynamic stability of kinetic Ising models

    Thomas Vojta 1997 J. Phys. A: Math. Gen. 30 L7

  3. Automated counting of mammalian cell colonies

    Paul R Barber et al 2001 Phys. Med. Biol. 46 63

  4. Magnetically-driven bi-directional optical microscanner

    Hyoung J Cho and Chong H Ahn 2003 J. Micromech. Microeng. 13 383

  5. Nonlinear tapping dynamics of multi-walled carbon nanotube tipped atomic force microcantilevers

    S I Lee et al 2004 Nanotechnology 15 416

  6. Advanced computational methods for simulating chemical reactions

    D L Thompson et al 2005 J. Phys.: Conf. Ser. 16 252

  7. A piezoelectric quad-morph actuated suspension for hard disk drives

    Gih Keong Lau and Hejun Du 2006 J. Micromech. Microeng. 16 1833

  8. Application of FIB technique to introduction of a notch into a carbon fiber for direct measurement of fracture toughness

    S Ogihara et al 2009 J. Phys.: Conf. Ser. 191 012009

  9. Analysis of a hybrid spectral strain estimation technique in elastography

    Kenneth Hoyt et al 2006 Phys. Med. Biol. 51 197

  10. Noninteger principal quantum numbers increase the efficiency of Slater-type basis sets: singly charged cations and anions

    Toshikatsu Koga and Katsutoshi Kanayama 1997 J. Phys. B: At. Mol. Opt. Phys. 30 1623

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.