Erythrocyte sedimentation rate studies in whole human blood

W T Hung, A F Collings and J Low

Show affiliations


Precise measurements have been made of the rate of sedimentation of whole blood in which the concentrations of red blood cells and the plasma proteins have been systematically varied. The contribution of each factor to the sedimentation process is expressed in terms of three parameters that describe the sedimentation curve: the set-up time, and the slopes of the first and second phases of settling. This analysis affords delineation between the onset and the degree of aggregation of the red blood cells as contributors to the usual ESR value, the height of plasma in a 200 nm blood column after 60 min. In terms of the 60 min ESR value, an increase in the haematocrit or albumin concentration inhibits sedimentation, the latter only slightly, whereas an increase in the concentration of globulin or fibrinogen accelerates sedimentation, with fibrinogen showing the more marked effect.


PACS

87.80.-y Biophysical techniques (research methods)

47.63.Jd Microcirculation and flow through tissues

47.57.ef Sedimentation and migration

87.19.rh Fluid transport and rheology

Subjects

Soft matter, liquids and polymers

Fluid dynamics

Instrumentation and measurement

Medical physics

Biological physics

Dates

Issue 11 (November 1994)



  1. Erythrocyte sedimentation rate studies in whole human blood

    W T Hung et al 1994 Phys. Med. Biol. 39 1855

  2. Lateral manipulation of single atoms at semiconductor surfaces using atomic force microscopy

    Noriaki Oyabu et al 2005 Nanotechnology 16 S112

  3. Prediction of respiratory tumour motion for real-time image-guided radiotherapy

    Gregory C Sharp et al 2004 Phys. Med. Biol. 49 425

  4. A public domain PC based treatment planning system

    H P Lawrence 1990 Phys. Med. Biol. 35 787

  5. Thermodynamics and thin film deposition of MgB2 superconductors

    X X Xi et al 2002 Supercond. Sci. Technol. 15 451

  6. Mass determination with the magnetic levitation method—proposal for a new design of electromechanical system

    H Kajastie et al 2009 Metrologia 46 298

  7. Exact image reconstruction on PI-lines from minimum data in helical cone-beam CT

    Yu Zou and Xiaochuan Pan 2004 Phys. Med. Biol. 49 941

  8. The medical physics of ventricular assist devices

    Houston G Wood et al 2005 Rep. Prog. Phys. 68 545

  9. Modulational instability, solitons and beam propagation in spatially nonlocal nonlinear media

    W Królikowski et al 2004 J. Opt. B: Quantum Semiclass. Opt. 6 S288

  10. Spin dynamics in rolled-up two-dimensional electron gases

    Maxim Trushin and John Schliemann 2007 New J. Phys. 9 346

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.