Quick search Find article
Quick search
Find article

Influence of the physical state and straggling on the computation of the radiation dose due to radon daughters deposited in the lung

A K M M Haque and I A M Al-affan

Show affiliations


The effect of the physical state (phase) of the absorbing medium and the energy straggling of the alpha particles on the calculation of the radiation dose due to the daughter products of radon deposited in the lung, have been studied in detail. The stopping power data for alpha particles in water and water vapour have been used. It has been found that the effect of straggling on the stopping power calculations is small, and therefore its contribution to dose calculations is negligible. The phase effect has been found to be dependent on the energy of the alpha particles and the depth in the medium. If the stopping power of water vapour is used instead of that for liquid water, the dose may be overestimated by 5-20 and 1-11% for 6 and 7.7 MeV alpha particles, respectively, at the beginning of alpha range, and underestimated by 15 and 40% respectively for the above energies at the end of the range.


PACS

87.53.-j Effects of ionizing radiation on biological systems

87.56.-v Radiation therapy equipment

87.53.Bn Dosimetry/exposure assessment

Subjects

Medical physics

Dates

Issue 8 (August 1987)



View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password