B M Wood and S Solve 2009 Metrologia 46 R13 doi:10.1088/0026-1394/46/6/R01
B M Wood1 and S Solve2
Show affiliationsIn March 2009, the Consultative Committee for Electricity and Magnetism (CCEM) reviewed and re-endorsed its recommendations originally proposed during its 25th meeting (April 2007) for changes in the SI electrical units (Recommendation E-1). Among its considerations, the document stated that the representation of the volt using the Josephson effect and the conventional value of the Josephson constant, KJ−90, has provided practical, accessible, reproducible, low noise and highly linear references worldwide since 1990. We summarize the measurement results of comparisons between Josephson voltage standards that help support this statement, especially concerning the accuracy and the simplicity of the Josephson relationship between voltage and frequency. We also detail a list of influence parameters and the ranges over which the Josephson relationship has been tested.
74.45.+c Proximity effects; Andreev effect; SN and SNS junctions
Issue 6 (December 2009)
Received 12 June 2009, in final form 26 August 2009
Published 7 October 2009
B M Wood and S Solve 2009 Metrologia 46 R13
A Picard et al 2009 Metrologia 46 1
S Westwood et al 2009 Metrologia 46 08019
Z Jiang 2008 Metrologia 45 S6
Enrico Bibbona et al 2008 Metrologia 45 S117
S Djordjevic et al 2008 Metrologia 45 429
G Petit and Z Jiang 2008 Metrologia 45 35
A Picard et al 2008 Metrologia 45 149
Joële Viallon et al 2008 Metrologia 45 08009
Guy Ratel 2007 Metrologia 44 S7