Quick search Find article
Quick search
Find article

Realizing the farad from two ac quantum Hall resistances

FEATURED ARTICLE

J Schurr1, V Bürkel1 and B P Kibble2

Show affiliations


[1]
von Klitzing K, Dorda G and Pepper M 1980 New method for high-accuracy determination of the fine structure constant based on quantized Hall resistance Phys. Rev. Lett. 45 494-7
CrossRef 
[2]
Jeckelmann B and Jeanneret B 2001 The quantum Hall effect as an electrical resistance standard Rep. Prog. Phys. 64 1603-56
IOPscience 
[3]
Delahaye F 1989 Technical guidelines for reliable measurements of the quantized Hall resistance Metrologia 26 63-8
IOPscience 
[4]
Delahaye F and Jeckelmann B 2003 Revised technical guidelines for reliable dc measurements of the quantized Hall resistance Metrologia 40 217-23
IOPscience 
[5]
Melcher J, Warnecke P and Hanke R 1993 Comparison of precision ac and dc measurements with the quantized Hall resistance IEEE Trans. Instrum. Meas. 42 292-4
CrossRef 
[6]
Hartland A, Kibble B P, Rodgers P J and Boháček J 1995 Ac measurements of the quantized Hall resistance IEEE Trans. Instrum. Meas. 44 245-8
CrossRef 
[7]
Wood B M, Inglis A D and Côté M 1997 Evaluation of the ac quantized Hall resistance IEEE Trans. Instrum. Meas. 46 269-72
CrossRef 
[8]
Chua S W, Hartland A and Kibble B P 1999 Measurement of the ac quantized Hall resistance IEEE Trans. Instrum. Meas. 48 309-13
CrossRef 
[9]
Schurr J, Melcher J, von Campenhausen A, Hein G, Ahlers F J and Pierz K 2002 AC behaviour of and loss phenomena in quantum Hall samples Metrologia 39 3-12
IOPscience 
[10]
Delahaye F, Kibble B P and Zarka A 2000 Controlling ac losses in quantum Hall effect devices Metrologia 37 659-70
IOPscience 
[11]
Overney F, Jeanneret B, Jeckelmann B, Wood B M and Schurr J 2006 The quantized Hall resistance: towards a primary standard of impedance Metrologia 43 409-13
IOPscience 
[12]
Schurr J, Ahlers F J, Hein G and Pierz K 2007 The ac quantum Hall effect as a primary standard of impedance Metrologia 44 15-23
IOPscience 
[13]
Ahlers F J, Jeanneret B, Overney F, Schurr J and Wood B M 2009 Compendium for precise ac measurements of the quantum Hall resistance Metrologia 46 R1-11
IOPscience 
[14]
Schurr J, Kibble B P, Hein G and Pierz K 2009 Controlling losses with gates and shields to perfect a quantum Hall impedance standard IEEE Trans. Instrum. Meas. 58 973-9
CrossRef 
[15]
Kibble B P and Schurr J 2008 A novel double-shielding technique for ac quantum Hall measurement Metrologia 45 L25-7
IOPscience 
[16]
Schurr J 2009 Impedance units from the quantum Hall effect McGraw-Hill Yearbook of Science and Technology (New York: McGraw-Hill) pp 179-81

[17]
Thompson A M and Lampard D G 1956 A new theorem in electrostatics and its application to calculable standards of capacitance Nature 177 888
CrossRef 
[18]
Gibbings D L H 1963 A design for resistors of calculable a.c./d.c. resistance ratio Proc. IEE 110 335-47
CrossRef 
[19]
Jones R and Kibble B P 1985 Realization of the SI ohm at NPL IEEE Trans. Instrum. Meas. 34 181-4
CrossRef 
[20]
Small G W, Ricketts B W, Coogan P C, Pritchard B J and Sovierzoski M M R 1997 A new determination of the quantized Hall resistance in terms of the NML calculable cross capacitor Metrologia 34 241-3
IOPscience 
[21]
Jeffery A, Elmquist R E, Shields J Q, Lee L H, Cage M E, Shields S H and Dziuba R F 1998 Determination of the von-Klitzing constant and the fine-structure constant through a comparison of the quantized Hall resistance and the ohm derived from the NIST calculable capacitor Metrologia 35 83-96
IOPscience 
[22]
Trapon G, Thévenot O, Lacueille J-C and Poirier W 2003 Determination of the von Klitzing constant RK in terms of the BNM calculable capacitor-fifteen years of investigations Metrologia 40 159-71
IOPscience 
[23]
Taylor B N and Witt T J 1989 New international electrical reference standards based on the Josephson and quantum Hall effects Metrologia 26 47-62
IOPscience 
[24]
Jeckelmann B, Jeanneret B and Inglis D 1997 High-precision measurements of the quantized Hall resistance: experimental conditions for universality Phys. Rev. B 55 13124-34
CrossRef 
[25]
Schopfer F and Poirier W 2007 Testing universality of the quantum Hall effect by means of the Wheatstone bridge J. Appl. Phys. 102 054903
CrossRef 
[26]
Jones K and Corney A C 1987 The PEL calculable capacitor Metrologia 24 1-11
IOPscience 
[27]
Mills I M, Mohr P J, Quinn T J, Taylor B N and Williams E R 2005 Redefinition of the kilogram: a decision whose time has come Metrologia 42 71-80
IOPscience 
[28]
Mills I M, Mohr P J, Quinn T J, Taylor B N and Williams E R 2006 Redefinition of the kilogram, ampere, kelvin and mole: a proposed approach to implementing CIPM recommendation 1 (CI-2005) Metrologia 43 227-46
IOPscience 
[29]
Scherer H, Lotkhov S V, Willenberg G D and Camarota B 2009 Progress towards the electron counting capacitance standard at PTB IEEE Trans. Instrum. Meas. 58 997-1002
CrossRef 
[30]
Kibble B P and Rayner G H 1984 Coaxial AC bridges (Bristol: Adam Hilger) obtainable from NPL, UK

[31]
Inglis A D, Wood B M, Côté M, Young R B and Early M D 2003 Direct determination of capacitance standards using a quadrature bridge and a pair of quantized Hall resistors IEEE Trans. Instrum. Meas. 52 559-62
CrossRef 
[32]
Delahaye F 1993 Series and parallel connection of multiterminal quantum Hall-effect devices J. Appl. Phys. 73 7914-20
CrossRef 
[33]
Delahaye F 1994/95 Accurate ac measurements of the quantized Hall resistance from 1 Hz to 1.6 kHz Metrologia 31 367-73
IOPscience 
[34]
Shields J Q 1965 Voltage dependence of precision air capacitors J. Res. Natl Bur. Std. C 69C 265-74

[35]
Final Report of EUROMET Project 540 available from the EURAMET project database, search for Ref. No. 540

[36]
Ramm G, Moser H and Schurr J 2009 Ultra-low-noise pre-amplifier and highly-stable sine generator for use in electrical ac quantum metrology Metrologia to be submitted

[37]
Hanke R 1989 An improved straddling method with triaxial guard for the calibration of inductive voltage dividers at 1592 Hz IEEE Trans. Instrum. Meas. 38 974-8
CrossRef 
[38]
Ramm G and Bachmair H 1982 Optimierung des Signal-zu-Rauschverhältnisses bei Wechselstrombrücken Tech. Mess. 49/9 321-4

[39]
Ramm G 1983 Rauscharme Wechselspannungsverstärker für den nV-Bereich Elektronik 5 82-6

crossref member

Related review articles

What's this?
View review articles related to this research to gain an insight into the key trends in this subject area. Related review articles are selected based on PACS/MSC codes, and are no more than three years old.

  1. Compendium for precise ac measurements of the quantum Hall resistance
  2. Quantum Hall effects in graphene-based two-dimensional electron systems
  3. Disordered topological insulators: a non-commutative geometry perspective
More

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.