Quick search Find article
Quick search
Find article

Accuracy evaluation of an optically pumped caesium beam frequency standard KRISS-1

Soo Heyong Lee1, Young-Ho Park2, Sang Eon Park1, Ho Seong Lee1, Sung Hoon Yang1, Dai-Hyuk Yu1 and Taeg Yong Kwon1

Show affiliations


We report on Korea's first optically pumped primary frequency standard (KRISS-1) developed at the Korea Research Institute of Standards and Science. Although a relatively small microwave cavity (the cavity drift region is about 36 cm in length) has been employed in this experiment, we achieved our desired frequency accuracy by applying the regularized inverse on the Ramsey spectrum analysis and compensating the effect of the evanescent field inside the cavity. KRISS-1 typically performs at a short term stability of 1.3\times 10^{-12}/\sqrt{\tau} with a combined uncertainty of 1.0 × 10−14.


PACS

06.20.fb Standards and calibration

07.57.Hm Infrared, submillimeter wave, microwave, and radiowave sources

Subjects

Instrumentation and measurement

Dates

Issue 3 (June 2009)

Received 12 November 2008, in final form 25 January 2009

Published 24 March 2009



  1. Accuracy evaluation of an optically pumped caesium beam frequency standard KRISS-1

    Soo Heyong Lee et al 2009 Metrologia 46 227

  2. Copper K-edge XANES of Cu(I) and Cu(II) oxide mixtures

    A Gaur et al 2009 J. Phys.: Conf. Ser. 190 012084

  3. General principles for the definition of the base units in the SI

    Volkmar Kose et al 2003 Metrologia 40 146

  4. Adaptive phase measurements in linear optical quantum computation

    T C Ralph et al 2005 J. Opt. B: Quantum Semiclass. Opt. 7 S245

  5. Specific Heat of Rhombohedral Polymeric C60 in Temperature Range 300–2 K

    Cui Guang-Lei et al 2008 Chinese Phys. Lett. 25 658

  6. A new algebraization of the Laméequation

    Federico Finkel et al 2000 J. Phys. A: Math. Gen. 33 1519

  7. Coherent Dynamics of Direct-Current-Driven Quantum-Dot-Array with Two Time-Dependent Embedded Impurities

    Li Xiu-Ping et al 2008 Chinese Phys. Lett. 25 1396

  8. XAFS study of the thermal behaviour of gold bulk and clusters

    T Comaschi et al 2009 J. Phys.: Conf. Ser. 190 012122

  9. Defects in amorphous Si1 − xGex alloys: An explanation of electron spin resonance signals

    E. Kim et al 1997 Europhys. Lett. 40 147

  10. On a possible mechanism for peripheral nerve stimulation during magnetic resonance imaging scans

    Lawrence K Forbes and Stuart Crozier 2001 Phys. Med. Biol. 46 591

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.