Joële Viallon et al 2009 Metrologia 46 08016 doi:10.1088/0026-1394/46/1A/08016
Joële Viallon1, Philippe Moussay1, Robert Wielgosz1 and Bernhard Niederhauser2
Show affiliationsAs part of the on-going key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Swiss Federal Office of Metrology (METAS) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone mole fraction range of 0 nmol/mol to 500 nmol/mol.
Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.
The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
Issue 1A (Technical Supplement 2009)
Joële Viallon et al 2009 Metrologia 46 08016
Willy Fischler et al JHEP09(2003)024
Andreas Birkedal et al JHEP10(2004)036
C Michotte et al 2009 Metrologia 46 06010
Yong Zhang et al 2008 J. Phys. A: Math. Theor. 41 055310
D T Burns 2003 Metrologia 40 06031
A V Gusev et al 2008 Class. Quantum Grav. 25 055006
G I Hay et al 2009 Smart Mater. Struct. 18 015015
Shouhu Xuan et al 2007 Nanotechnology 18 035602
C Eiø and J Howes 2009 Metrologia 46 01006