Quick search Find article
Quick search
Find article

Final report on APMP.M.P-K6.1 pneumatic key comparison from 20 kPa to 105 kPa in gauge mode

Chen-Chuan Hung1, Wu Jian2 and Tawat Changpan3

Show affiliations


KEY COMPARISON

This report describes the key comparison APMP.M.P-K6.1 among the three national metrology institutes, Center for Measurement Standards–ITRI (CMS-ITRI, Taiwan), SPRING Singapore and National Institute of Metrology (NIMT), in the pressure range from 20 kPa to 105 kPa in gas media and gauge mode executed during the period April 2003 to April 2004. This comparison was conducted by CMS-ITRI and was based on the calibration procedure of APMP pneumatic pressure comparison APMP.M.P-K6. We intended to link to the CCM.P-K6 key comparison through the APMP.M.P-K6 key comparison by using the proposed linkage method in the APMP.M.P-K6 key comparison to determine a linking factor that can transform the quantities measured in the APMP.M.P-K6.1 key comparison. All three participating institutes used pneumatic piston gauges as their pressure standards. The Ruska 2465 gas-operated piston–cylinder assembly TL-1409 used as transfer standard offered by CMS-ITRI was calibrated three times by the pilot institute during the comparison period and showed that it was very stable after evaluation. The comparison was conducted on the basis of cross-float experiments to determine the effective area of transfer standards from the national standards of three institutes.

The comparison results (as shown in Table 6) were equivalent to the CCM.P-K6 comparison and the relative bilateral degrees of equivalence between two laboratories were smaller than 39.7 × 10-6 from 20 kPa to 105 kPa. These results showed all participating institutes measuring the same quantity in the whole pressure range lay within their expanded uncertainty with confidence level 95%.

Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.

The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).


Dates

Issue 1A ( 1 January 2009)



  1. Final report on APMP.M.P-K6.1 pneumatic key comparison from 20 kPa to 105 kPa in gauge mode

    Chen-Chuan Hung et al 2009 Metrologia 46 07004

  2. Generalizing resolution

    Philip B Stark 2008 Inverse Problems 24 034014

  3. Bistable nanowire for micromechanical memory

    B Charlot et al 2008 J. Micromech. Microeng. 18 045005

  4. CCQM K27 (a, b): Determination of ethanol in aqueous matrix

    K S Webb and C S J Wolff Briche 2004 Metrologia 41 08002

  5. The Child–Langmuir law and analytical theory of collisionless to collision-dominated sheaths

    M S Benilov 2009 Plasma Sources Sci. Technol. 18 014005

  6. Signatures of supernova neutrino oscillations in the Earth mantle and core

    A S Dighe et al JCAP01(2004)004

  7. On the possibility of large axion decay constants

    Tom Banks et al JCAP06(2003)001

  8. New reducible five-brane solutions in M-theory

    Richard Clarkson et al JHEP08(2004)025

  9. A critical assessment of the elastic properties and effective wall thickness of single-walled carbon nanotubes

    C Y Wang and L C Zhang 2008 Nanotechnology 19 075705

  10. Quasi-normal modes of warped black holes and warped AdS/CFT correspondence

    Bin Chen and Zhi-bo Xu JHEP11(2009)091

View by subject




Export





Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.