Activity measurements of a suite of radionuclides (90Sr, 137Cs, 210Pb, 210Po, 228Ra, 234U, 235U, 238U, 238Pu, 239,240Pu) in soil reference material (Rocky Flats II): CCRI(II)-S2

S Nour1, K G W Inn2 and L R Karam2

Show affiliations


SUPPLEMENTARY COMPARISON

In 2005, the CCRI decided that a comparison undertaken from 2002 to 2007 by the NIST (SIM) in the development of a new soil (Rocky Flats II) standard reference material (SRM) was sufficiently well constructed that it could be converted into a supplementary comparison under CCRI(II), with comparison identifier CCRI(II)-S2, so as to support calibration and measurement capability (CMC) claims for radionuclide measurements in reference material (specifically, low calcium-content soils). Previous comparisons of radionuclides have been of single or multiple nuclides in non-complex matrices and results of such could not be extended to support capabilities to measure the same nuclides in reference materials. The results of this comparison have been reported to the participants, and have been used to determine the certified reference value of the SRM. The key comparison working group (KCWG) of the CCRI(II) has approved this approach as a mechanism to link all the results to certified 'reference values' in lieu of the key comparison reference value (KCRV) of these specified radionuclides in this type of matrix (soil) so as to support CMCs of similar materials.

Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.

The final report has been peer-reviewed and approved for publication by the CCRI Section II, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).


Dates

Issue 1A ( 1 January 2009)



  1. Activity measurements of a suite of radionuclides (90Sr, 137Cs, 210Pb, 210Po, 228Ra, 234U, 235U, 238U, 238Pu, 239,240Pu) in soil reference material (Rocky Flats II): CCRI(II)-S2

    S Nour et al 2009 Metrologia 46 06003

  2. Fabrication of a miniature diamond grinding tool using a hybrid process of micro-EDM and co-deposition

    Shun-Tong Chen et al 2008 J. Micromech. Microeng. 18 055005

  3. Attosecond metrology in the few-optical-cycle regime

    G Sansone et al 2008 New J. Phys. 10 025006

  4. Ultrafast decay of femtosecond laser-induced grating in silicon-quantum-dot-based optical waveguides

    I Pelant et al 2008 J. Phys. D: Appl. Phys. 41 015103

  5. A real-time assessment of measurement uncertainty in the experimental characterization of sprays

    M R O Panão and A L N Moreira 2008 Meas. Sci. Technol. 19 095402

  6. A proof-of-principle experiment of eliminating photon-loss errors in cluster states

    Wei-Bo Gao et al 2008 New J. Phys. 10 055003

  7. Reverse Monte Carlo modelling of amorphous Si3B3N7 using scattering and 15N NMR data

    Markus Doerr and Christel M Marian 2007 J. Phys.: Condens. Matter 19 056201

  8. BIPM comparison BIPM.RI(II)-K1.Sm-153 of activity measurements of the radionuclide 153Sm

    G Ratel and C Michotte 2004 Metrologia 41 06012

  9. Theory of cylindrical Langmuir probes in weakly ionized, non-thermal, stationary and moderately collisional plasmas

    P M Bryant 2009 Plasma Sources Sci. Technol. 18 014013

  10. Searching for new physics with ultrahigh energy cosmic rays

    Floyd W Stecker and Sean T Scully 2009 New J. Phys. 11 085003

View by subject




Export





Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.