Quick search Find article
Quick search
Find article

Final report on APMP.L-K1.1: Calibration of gauge blocks by interferometry

Akiko Hirai1, K P Chaudhary2, Ahmad Makinudin Bin Dahlan3, Eleanor Howick4, Yu-Ping Lan5, Anusorn Tonmueanwai6 and Bui Quoc Thu7

Show affiliations


KEY COMPARISON

The results of the APMP key comparison on calibration of gauge blocks by interferometry (APMP.L-K1.1) are reported. The comparison was planned to follow up the previous comparison APMP.L-K1. The comparison involved the measurement, by seven participating institutes, of ten steel gauge blocks ranging from 0.5 mm to 100 mm in length using techniques based on interferometry. The results are analyzed using En values with weighted mean values as the reference values. For calculating the reference values some measurement results had to be excluded by application of the En-criterion. Investigations of the reasons for the deviations have already been started by the respective institutes.

Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.

The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).


Dates

Issue 1A (Technical Supplement 2009)



View by subject




Export





Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.