Miguel Viliesid 2009 Metrologia 46 04003 doi:10.1088/0026-1394/46/1A/04003
Miguel Viliesid
Show affiliationsThe Mutual Recognition Arrangement of the CIPM indicates that a metrological equivalence of national measurement standards and calibration certificates issued by national metrology institutes (NMIs) should be established by a set of key comparisons chosen and organized by the Consultative Committees of the Comité Internationale des Poids et Mesures on key techniques. The CCL (Comité Consultative de Longueur), identified several key comparisons in the field of dimensional metrology. In particular, it decided that a coordinate measuring machine (CMM) two-dimensional (2-D) artifact should be carried out. CENAM (Centro Nacional de Metrología) was designated as pilot laboratory and NMIs of signatories of the Metre Convention were invited to participate. The comparison is aimed to support the Calibration and Measurement Capabilities (CMCs) claims of NMIs for CMM 2-D standards calibration.
Twelve NMIs from four Regional Metrology Organizations finished the comparison and one withdrew. The final participants were as follows:
A Draft B report was circulated among the participants and, after review and approval by all of the participants, it became the final report. It comprises all the information about the comparison: the measurement results, the choice of a Key Comparison Reference Value, the estimation of its uncertainty, the performance of each participant with respect to this value and the Birge ratio for each measurand of the two artifacts.
It was decided afterwards at CCL that the exercise be classed as a supplementary comparison but the reference of CCL-K6 was kept.
In an Appendix the equivalences of all measurands of each laboratory with respect to the reference value are reported for both artifacts, as well as the pairwise equivalences between laboratories for all measurands of both artifacts. The results are shown on tables as well as in plots.
The comparison was scheduled to start in January 2001 and span the circulation until December 2002. The circulation scheme was delayed for many reasons. It finally ended in September 2004.
The following main conclusions may be drawn:
Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.
The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
Issue 1A (Technical Supplement 2009)
Miguel Viliesid 2009 Metrologia 46 04003
O A Kruger 2009 Metrologia 46 04004
Andrew Lewis and Nicola Testa 2009 Metrologia 46 04002
L Koenders et al 2004 Metrologia 41 04001
Otto Jusko et al 2006 Metrologia 43 04006
Howard McQuoid and Zbigniew Ramotowski 2008 Metrologia 45 04002
Nimai C Nayak et al 2008 J. Micromech. Microeng. 18 095020
Ko Hermans et al 2008 J. Micromech. Microeng. 18 095022
Andrew Lewis 2006 Metrologia 43 04003
G C Sharp et al 2007 Phys. Med. Biol. 52 5771