Bilateral comparison of 1 Ω standards (ongoing BIPM key comparison BIPM.EM-K13.a) between the NMIA (Australia) and the BIPM

R Goebel1, N Fletcher1, M Stock1, B Pritchard2, Raymond Xie2, Peter Coogan2 and Leigh Johnson2

Show affiliations


KEY COMPARISON

This report describes the results obtained from a NMIA(Australia)–BIPM bilateral comparison of 1 Ω resistance standards in the period 2008–2009. The comparison was carried out in the framework of the BIPM ongoing key comparison BIPM.EM-K13.a. Three BIPM 1 Ω travelling standards of CSIRO type were calibrated first at the BIPM, then at the NMIA and again at the BIPM after their return. The stability of the transfer standards was such that the uncertainty associated with the transfer was significantly smaller than the uncertainty arising from the calibrations.

The BIPM results are based on the conventional value RK-90. Those from the NMIA are traceable to a calculable capacitor. The uncertainty of the comparison includes therefore the standard uncertainty of 1 × 10−7 that applies to the use of the quantum Hall effect as a representation of the ohm.

The NMIA and the BIPM calibrations were found to be in agreement, with a mean difference smaller than the expanded uncertainty (k = 2) of the comparison.

Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.

The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).


Dates

Issue 1A (Technical Supplement 2009)



  1. Bilateral comparison of 1 Ω standards (ongoing BIPM key comparison BIPM.EM-K13.a) between the NMIA (Australia) and the BIPM

    R Goebel et al 2009 Metrologia 46 01011

  2. Bilateral comparison of 1.018 V and 10 V standards between the INTI (Argentina) and the BIPM, August to October 2009 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    A Tonina et al 2010 Metrologia 47 01002

  3. Bilateral comparison of 10 V standards between the NML (Ireland) and the BIPM, April to May 2009 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    O Power et al 2009 Metrologia 46 01008

  4. Comparison of the Josephson Voltage Standards of the KRISS and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b)

    S Solve et al 2008 Metrologia 45 01006

  5. Comparison of the Josephson voltage standards of the SMD and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b)

    S Solve et al 2010 Metrologia 47 01004

  6. Final report on bilateral comparison of 10 kΩ standards (ongoing BIPM key comparison BIPM.EM-K13.b) between the NIMT-Thailand and the BIPM

    R Goebel et al 2010 Metrologia 47 01005

  7. A review of Josephson comparison results

    B M Wood and S Solve 2009 Metrologia 46 R13

  8. Solution of an X-ray edge problem: the recoil spectrum of a suddenly perturbed Fermi sea

    J D Dow and C P Flynn 1980 J. Phys. C: Solid State Phys. 13 1341

  9. A fibre optic evanescent wave sensor used for the detection of trace nitrites in water

    P Suresh Kumar et al 2002 J. Opt. A: Pure Appl. Opt. 4 247

  10. Evanescent wave fibre optic sensors for trace analysis of Fe3+ in water

    S Thomas Lee et al 2003 Meas. Sci. Technol. 14 858

View by subject




Export





Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.